14.10. In the event that the Goods are returned for repair under Warranty, and Brüllen determines that the repair is not
covered under Warranty, the Client will be advised in writing. Brüllen will not perform any further work beyond
establishing the nature of the repairs required, without the prior written consent of the Client.
14.11. All Warranty and other services, (other than ongoing system cleaning cycles) are to be carried out by Brüllen, or
a Brüllen Accredited Technician. The Client is responsible for insuring the Goods during any process of de-
installation and transport. Brüllen will not be liable for any loss or damage arising from same.
14.12. To the maximum extent permitted by law, the decision of Brüllen in all Warranty matters will be final.
14.13. If this Warranty is void by reason of paragraphs 6 and 7 above, this Warranty may be tendered as a complete
defence to any legal proceedings.
15. Troubleshooting
15.1. Refrigeration Fault
15.2. Product Dispensing Issues
DESCRIPTION
CAUSE
SOLUTION
Refrigeration
Fault
The starter capacitor
is faulty
The compressor or
controlling board is faulty
The voltage is too low, or
the power cable is too small
causing a voltage drop
Change out faulty
parts
Check power
supply and
voltage
Check refrigerant levels
Check for moisture source
around condenser
Locate leak and evacuate
system, repair and charge
system with refrigerant
Remove moisture
Source
System has a leak
Locate leak and evacuate
system, repair and charge
system with refrigerant
DESCRIPTION
ERROR
CAUSE
SOLUTION
Product
Dispensing
Issues
Freeze−up in mix inlet
hole.
Product is frozen solid in
the inlet hole causing
starvation to the freezing
cylinder
Call service technician to
adjust the mix hopper
temperature.
Not enough mix in
freezing chamber
The bottom hole of feed
tube is blocked
Mix level is to low
Remove feed tube and clean
Add mix
Product is too hard
The hardness setting is
too high
Decrease hardness setting and
allow one minute for change to
take effect
Product is too soft
Hardness needs
adjustment.
Adjust hardness settings.
Allow for adequate air flow