Risk of damage by using softened water!
– When using a lime transforming cartridge never
use softened water.
The use of softened water can cause damage to the
lime transforming cartridge.
8.5.1
Cleaning the UV degermination system and lime transforming cartridge
Personnel:
n
Operator
Protective equip-
ment:
n
Chemical-resistant protective
gloves
n
Protective goggles
Materials:
n
Lime remover
L WARNING! Risk of electrical shock if the power
plug is not disconnected!
1.
Switch off humidifier and disconnect power plug.
2.
Lift the cover of the humidifier upwards and place
to the side (Fig. 63).
NOTICE
Clean UV degermination
system
Fig. 63: Remove cover
Accessories
2013-11-04Evaporation Humidifier B500 Professional72