5.
L WARNING! Danger of poisoning and
damage from careless removal of the UV lamp!
Carefully pull out the UV lamp on the connection
cable (Fig. 73).
6.
Only touch the UV lamp at its blue end pieces.
Remove connection cable of UV lamp (Fig. 74).
7.
Seize the new UV lamp on the end caps and
unpack.
8.
Attach connection cable to the new UV lamp.
9.
Carefully insert the UV lamp into the quartz glass
body.
10.
Place the control panel again and fasten using the
four screws.
11.
Replace cover of device.
Fig. 73: Pulling out the UV lamp
Fig. 74: Remove connection
cable
Accessories
2013-11-04 Evaporation Humidifier B500 Professional 77