03 SAFETY PRECAUTIONS
Initial operation
The paint coat of the stove is not completely hardened before reaching
normal operating temperature for the rst time. Smoke emissions and
unpleasant odours cannot be excluded. Therefore, provide sufficient ven-
tilation of the room when lighting the re. Open all doors and windows,
use an electric fan if necessary, to ensure faster air exchange within the
room. During first operation try to avoid staying in this room for too long,
if possible.
The combustion chamber door
BRUNNER fireplaces are only intended for operation with the combustion
chamber door closed. In the case of open operation or opening during
combustion, there is a risk of heating gases escaping into the living area.
If the fireplace is not in use, the combustion chamber door remains closed.
Risk of burns
External surfaces of the fireplace, in particular the glass door, may get very
hot. Do not touch - risk of burns! Remember to warn your children about
this. Basically, children should stay away from a burning stove. Objects
made of ammable materials may not be placed on available surfaces of
the fireplace. Flammable textile fabrics must have a minimum distance of
5 cm from the vertical surfaces of the fireplace.
For your own security, store the ashes in a fire-resistant container for at
least 24 hours before you dispose of them - Fire hazard! In case of fire call
the fire brigade immediately! In the case of chimneyre move allamma-
ble parts and elements away from the chimney. Watch out for ying sparks.
Never use petrol or alcohol to light a fire!
2
80 cm with coated glass pane (GKB = coated glass ceramic)
Air gratings
Do not close or cover up the warm air vents of your replace. Risk of fire
or overheating!
Fireplaces with electronic control system
After closing the combustion chamber door of the fireplace, a message
must be displayed, informing that the combustion has been started (see
User Guide of the electronic control)! If this is not the case, the door con-
tact switches are defective! Risk of deflagration! Consult your stove fitter
and follow the instructions in chapter Heating with manually controlled
combustion air supply” of the User Guide for the electronic control EAS.
Heat radiation area
Do not bring any flammable objects into the radiation area of the viewing
pane up to a distance of 120/80 cm from the fireplace door (measured
from the glass pane)
2
Risk of fire! Do not leave any objects from ammable
materials in front of the fireplace door/glass pane.
Tunnel variants
In case of fireplaces with two glass panes on opposite sides (Tunnel vari-
ants), the operation and opening of the combustion door is only available
on one side. Only one fireplace door can be opened during use.
When both fireplace doors are opened, air blows can lead to smoke
release.
For versions with electronic combustion control it is not possible to
load wood and start fire on revision door side.