Do you have a question about the Brunswick BIOFLO 3000 and is the answer not in the manual?
Outlines the manual's content and scope for the BioFlo 3000 system.
Provides an overview of the BioFlo 3000 bioreactor system and its capabilities.
Details the construction and features of the BioFlo 3000's glass and stainless steel vessel.
Explains the servo motor, speed control, and PID loop for agitation in the BioFlo 3000.
Describes the temperature control system, range, and sensor used in the BioFlo 3000.
Covers the aeration system, gas introduction, and flow rate control for the BioFlo 3000.
Details the pH control system, range, electrode, and pump operation in the BioFlo 3000.
Explains the Dissolved Oxygen control system, range, sensors, and control methods for the BioFlo 3000.
Describes the foam control mechanism using an antifoam probe and pump in the BioFlo 3000.
Covers the exhaust system, including the condenser and filter for the BioFlo 3000.
Details the two systems available for collecting samples from the BioFlo 3000.
Lists the technical specifications for the BioFlo 3000's vessel, temperature, agitation, exhaust, aeration, pH, and DO.
Explains the membrane keypad, screen selection, and mode selection for operating the BioFlo 3000.
Instructions for inspecting the BioFlo 3000 for damage after shipping and verifying components.
Lists the necessary water, gas, and electrical utility requirements for installing the BioFlo 3000.
Provides steps for positioning, leveling, and connecting the BioFlo 3000 console.
Locates the main power switch and provides checks before turning on the system.
Describes the recorder output pins and specifications for connecting an external recorder.
Details the 25-pin "D" connector for computer interface and pin designations.
Step-by-step guide for cleaning the BioFlo 3000 vessel using detergent, water, and sterilization.
Instructions for assembling the BioFlo 3000 vessel, including impellers, probes, and headplate.
Guidance on inspecting and preparing the pH electrode, including electrolyte level and air bubbles.
Describes the correct procedure for installing the pH electrode, including safety precautions.
Provides instructions for maintaining and storing the pH probe, including filling solution and storage conditions.
Details the step-by-step process for calibrating the pH electrode using buffer solutions.
Instructions for handling, sterilizing, and installing the DO probe for optimal performance.
Comprehensive guide for sterilizing the BioFlo 3000 vessel, components, and probes using an autoclave.
Step-by-step methods for performing zero and span calibration for the D.O. electrode.
Outlines the final steps to prepare the BioFlo 3000 system for operation after assembly and calibration.
Explains how the system controls D.O. by adjusting agitation speed and oxygen output.
Provides detailed steps for collecting samples aseptically from the BioFlo 3000 vessel.
Outlines the correct steps for safely shutting down the BioFlo 3000 system.
Offers practical advice for assembling the glass vessel, cleaning components, and calculating OTR.
Discusses the importance of preventive maintenance for equipment longevity and reducing downtime.
Provides instructions for cleaning the BioFlo 3000 console using a damp cloth and mild detergent.
Details checks and inspections to be performed at three-month intervals to ensure proper operation.
Specifies cleaning procedures for the vessel, headplate, and associated parts after each run.
Guides on maintaining and storing D.O. and pH probes, including lifespan and storage conditions.
Recommends checking and cleaning the agitator bearing housing components every 3-6 months.
Lists part numbers for various components of the BioFlo 3000 system.
Lists the part numbers for basic vessel assemblies for different total volumes.
Lists part numbers for the Fixed Bed Kit for different total volumes.
Lists part numbers for the Cell Lift Impeller Kit for different total volumes.
Lists part numbers for the Marine Blade Impeller Kit for different total volumes.
Lists part numbers for the Pitched Blade Impeller Kit for different total volumes.
Lists part numbers for probe kits for specific impeller applications and total volumes.
Lists part numbers for probe kits specifically for the Fixed Bed Reactor.
Lists part numbers and voltage for Perfusion Kits for Cell Lift applications.
Lists part numbers and total volume for Perfusion Kits for Fixed Bed applications.
Describes the contents of the Conversion Kit, including a CelliGen Plus manual and motor.
Outlines the manual's content and scope for the BioFlo 3000 system.
Provides an overview of the BioFlo 3000 bioreactor system and its capabilities.
Details the construction and features of the BioFlo 3000's glass and stainless steel vessel.
Explains the servo motor, speed control, and PID loop for agitation in the BioFlo 3000.
Describes the temperature control system, range, and sensor used in the BioFlo 3000.
Covers the aeration system, gas introduction, and flow rate control for the BioFlo 3000.
Details the pH control system, range, electrode, and pump operation in the BioFlo 3000.
Explains the Dissolved Oxygen control system, range, sensors, and control methods for the BioFlo 3000.
Describes the foam control mechanism using an antifoam probe and pump in the BioFlo 3000.
Covers the exhaust system, including the condenser and filter for the BioFlo 3000.
Details the two systems available for collecting samples from the BioFlo 3000.
Lists the technical specifications for the BioFlo 3000's vessel, temperature, agitation, exhaust, aeration, pH, and DO.
Explains the membrane keypad, screen selection, and mode selection for operating the BioFlo 3000.
Instructions for inspecting the BioFlo 3000 for damage after shipping and verifying components.
Lists the necessary water, gas, and electrical utility requirements for installing the BioFlo 3000.
Provides steps for positioning, leveling, and connecting the BioFlo 3000 console.
Locates the main power switch and provides checks before turning on the system.
Describes the recorder output pins and specifications for connecting an external recorder.
Details the 25-pin "D" connector for computer interface and pin designations.
Step-by-step guide for cleaning the BioFlo 3000 vessel using detergent, water, and sterilization.
Instructions for assembling the BioFlo 3000 vessel, including impellers, probes, and headplate.
Guidance on inspecting and preparing the pH electrode, including electrolyte level and air bubbles.
Describes the correct procedure for installing the pH electrode, including safety precautions.
Provides instructions for maintaining and storing the pH probe, including filling solution and storage conditions.
Details the step-by-step process for calibrating the pH electrode using buffer solutions.
Instructions for handling, sterilizing, and installing the DO probe for optimal performance.
Comprehensive guide for sterilizing the BioFlo 3000 vessel, components, and probes using an autoclave.
Step-by-step methods for performing zero and span calibration for the D.O. electrode.
Outlines the final steps to prepare the BioFlo 3000 system for operation after assembly and calibration.
Explains how the system controls D.O. by adjusting agitation speed and oxygen output.
Provides detailed steps for collecting samples aseptically from the BioFlo 3000 vessel.
Outlines the correct steps for safely shutting down the BioFlo 3000 system.
Offers practical advice for assembling the glass vessel, cleaning components, and calculating OTR.
Discusses the importance of preventive maintenance for equipment longevity and reducing downtime.
Provides instructions for cleaning the BioFlo 3000 console using a damp cloth and mild detergent.
Details checks and inspections to be performed at three-month intervals to ensure proper operation.
Specifies cleaning procedures for the vessel, headplate, and associated parts after each run.
Guides on maintaining and storing D.O. and pH probes, including lifespan and storage conditions.
Recommends checking and cleaning the agitator bearing housing components every 3-6 months.
Lists part numbers for various components of the BioFlo 3000 system.
Lists the part numbers for basic vessel assemblies for different total volumes.
Lists part numbers for the Fixed Bed Kit for different total volumes.
Lists part numbers for the Cell Lift Impeller Kit for different total volumes.
Lists part numbers for the Marine Blade Impeller Kit for different total volumes.
Lists part numbers for the Pitched Blade Impeller Kit for different total volumes.
Lists part numbers for probe kits for specific impeller applications and total volumes.
Lists part numbers for probe kits specifically for the Fixed Bed Reactor.
Lists part numbers and voltage for Perfusion Kits for Cell Lift applications.
Lists part numbers and total volume for Perfusion Kits for Fixed Bed applications.
Describes the contents of the Conversion Kit, including a CelliGen Plus manual and motor.