042-D, E
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AC048 39,000 TDR — 12.50 — — 10.75 40,000 3.06 25,200 2.34 7.0
CC5A/CD5AW048 39,500 TDR — 13.00 — — 10.95 40,500 3.24 25,400 2.42 7.3
CD5AA048 39,500 TDR — 13.00 — — 10.95 40,500 3.24 25,400 2.40 7.3
CK3BA048 40,000 TDR — 13.00 — — 11.10 40,500 3.36 25,400 2.46 7.5
CK5A/CK5BA048 40,000 TDR — 13.00 — — 11.10 40,500 3.36 25,400 2.46 7.5
CK5A/CK5BT048 40,000 TDR — 13.00 — — 11.10 40,500 3.36 25,400 2.46 7.5
CK5A/CK5BW048 40,000 TDR — 12.50 — — 10.80 40,500 3.32 25,600 2.44 7.5
CK5PA048 40,000 TDR&TXV 13.00 — — — 11.10 40,500 3.36 25,400 2.46 7.5
CK5PT048 40,000 TDR&TXV 13.00 — — — 11.10 40,500 3.36 25,400 2.46 7.5
CK5PW048 40,000 TDR&TXV 12.50 — — — 10.80 40,500 3.32 25,600 2.44 7.5
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AC048 39,000 TDR — 13.00 — — 10.80 40,000 3.06 25,200 2.34 7.0
CC5A/CD5AW048 40,000 TDR — 13.00 — — 11.05 40,500 3.22 25,200 2.40 7.3
CD5AA048 39,500 TDR — 13.00 — — 11.00 40,500 3.22 25,400 2.42 7.3
CK5A/CK5BW048 40,000 TDR — 13.00 — — 11.05 40,500 3.36 25,400 2.46 7.5
CK5PW048 40,000 TDR&TXV 13.00 — — — 11.05 40,500 3.36 25,400 2.46 7.5
048-D,
E, F
*FV4BNF005 45,500 TDR&TXV 13.50 — — — 11.60 47,500 3.58 27,600 2.46 8.5
CC5A/CD5AA060 44,500 NONE — 12.20 — — 10.60 48,000 3.22 28,400 2.26 7.9
CC5A/CD5AW060 44,500 NONE — 12.50 — — 10.80 48,000 3.40 28,400 2.34 8.1
CD5PX060 44,500 TXV — — — 13.00 11.00 46,500 3.18 27,400 2.28 7.5
CE3AA060 45,500 NONE — 12.50 — — 10.80 48,000 3.40 28,400 2.34 8.0
CK3BA060 45,000 NONE — 12.50 — — 10.75 48,000 3.50 28,600 2.38 8.2
CK5A/CK5BA060 45,000 NONE — 12.50 — — 10.75 48,000 3.50 28,600 2.38 8.2
CK5A/CK5BT060 45,000 NONE — 12.50 — — 10.75 48,000 3.50 28,600 2.38 8.2
CK5A/CK5BX060 45,500 NONE — 13.00 — — 10.90 48,500 3.52 28,600 2.38 8.3
CK5PA060 45,000 TXV — — — 12.50 10.75 48,000 3.50 28,600 2.38 8.2
CK5PT060 45,000 TXV — — — 12.50 10.75 48,000 3.50 28,600 2.38 8.2
CK5PX060 45,500 TXV — — — 13.00 10.90 48,500 3.52 28,600 2.38 8.3
F(A,B)4BN(F,B,C)060 44,500 TDR — — 11.70 — 10.20 48,500 3.32 29,000 2.26 7.8
FB4BNB070 46,000 TDR — — 12.50 — 10.90 48,000 3.54 28,600 2.38 8.0
FC4CN(F,B)060 44,500 TDR&TXV — — 11.70 — 10.20 48,000 3.32 29,000 2.26 7.7
FC4CNB070 46,000 TDR&TXV — — 12.50 — 10.90 48,000 3.54 28,600 2.38 8.0
FE4ANB006 46,500 TDR&TXV 14.10 — — — 12.05 48,000 3.76 27,600 2.54 8.6
FE4ANF005 45,500 TDR&TXV 13.50 — — — 11.60 47,500 3.58 27,600 2.46 8.5
FK4DNB006 46,500 TDR&TXV — — 14.00 — 12.05 48,000 3.76 27,600 2.54 8.5
FK4DNF005 45,500 TDR&TXV — — 13.20 — 11.60 48,000 3.58 27,800 2.46 8.2
FV4BNB006 46,500 TDR&TXV 14.10 — — — 12.05 48,000 3.76 27,600 2.54 8.6
FX4BNB060 45,500 TDR&TXV 12.60 — — — 10.90 48,000 3.54 28,600 2.38 8.1
FX4BNF048 45,000 TDR&TXV 12.50 — — — 10.75 48,000 3.42 28,400 2.34 8.0
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CE3AA060 44,500 TDR — — 13.00 — 11.40 47,500 3.64 27,400 2.50 8.5
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
CD5PX060 45,000 TDR&TXV 13.50 — — — 11.70 48,000 3.68 27,600 2.50 8.5
CE3AA060 45,000 TDR — — 13.50 — 11.60 47,500 3.42 27,800 2.40 8.1
CK3BA060 44,500 TDR — — 13.50 — 11.60 47,500 3.60 27,600 2.46 8.3
CK5A/CK5BA060 44,500 TDR — — 13.50 — 11.60 47,000 3.48 27,400 2.42 8.1
CK5A/CK5BT060 44,500 TDR — — 13.50 — 11.60 47,500 3.60 27,600 2.46 8.3
CK5A/CK5BX060 45,500 TDR — — 14.00 — 11.85 47,500 3.60 27,600 2.46 8.3
CK5PA060 44,500 TDR&TXV 13.50 — — — 11.60 47,500 3.60 27,600 2.46 8.3
CK5PT060 44,500 TDR&TXV 13.50 — — — 11.60 47,500 3.60 27,600 2.46 8.3
CK5PX060 45,500 TDR&TXV 14.00 — — — 11.85 47,500 3.62 27,600 2.50 8.5
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AW060 44,500 TDR — — 13.50 — 11.60 47,000 3.46 27,400 2.42 8.1
CE3AA060 45,000 TDR — — 13.50 — 11.60 47,000 3.48 27,400 2.42 8.1
CK3BA060 44,500 TDR — — 13.50 — 11.55 47,500 3.58 27,600 2.46 8.3
CK5A/CK5BA060 44,500 TDR — — 13.50 — 11.55 47,500 3.62 27,600 2.50 8.5
CK5A/CK5BT060 44,500 TDR — — 13.50 — 11.55 47,500 3.58 27,600 2.46 8.3
CK5A/CK5BX060 45,500 TDR — — 14.00 — 11.75 47,500 3.58 27,600 2.46 8.3
CK5PA060 44,500 TDR&TXV 13.50 — — — 11.55 47,500 3.58 27,600 2.46 8.3
CK5PT060 44,500 TDR&TXV 13.50 — — — 11.55 47,500 3.58 27,600 2.46 8.3
CK5PX060 45,500 TDR&TXV 14.00 — — — 11.75 47,500 3.62 27,600 2.48 8.3
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AW060 44,500 TDR — — 13.50 — 11.70 47,000 3.28 27,200 2.34 7.8
CE3AA060 45,000 TDR — — 13.50 — 11.70 47,000 3.46 27,600 2.42 8.1
CK3BA060 44,500 TDR — — 13.50 — 11.65 47,500 3.60 27,400 2.48 8.3
CK5A/CK5BA060 44,500 TDR — — 13.50 — 11.65 47,500 3.62 27,600 2.48 8.3
CK5A/CK5BT060 44,500 TDR — — 13.50 — 11.65 47,500 3.60 27,400 2.48 8.3
CK5A/CK5BX060 45,500 TDR — — 14.00 — 11.85 47,500 3.60 27,400 2.48 8.3
CK5PA060 44,500 TDR&TXV 13.50 — — — 11.65 47,500 3.60 27,400 2.48 8.3
CK5PT060 44,500 TDR&TXV 13.50 — — — 11.65 47,500 3.60 27,400 2.48 8.3
CK5PX060 45,500 TDR&TXV 14.00 — — — 11.85 47,500 3.64 27,400 2.50 8.5
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 43,000 TDR — 13.00 — — 10.95 46,500 3.22 27,400 2.30 7.5
CC5A/CD5AW048 43,000 TDR — 13.00 — — 10.95 47,000 3.48 27,400 2.44 8.0
CK3BA060 44,500 TDR — — 12.50 — 10.90 47,500 3.44 28,200 2.36 8.1
CK5A/CK5BA060 45,000 TDR — — 12.50 — 10.90 47,500 3.44 28,200 2.36 8.1
UNIT
SIZE-
SERIES
INDOOR
UNIT CFM††
ARI STANDARD RATINGS*
Cooling Heating
TC
Seasonal Efficiency SEER
EER
High-Temp Low-Temp
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
Puron
TXV
Puron
TXV
& TDR**
TC COP TC COP
COMBINATION RATINGS continued
See notes on page 15.