COMPONENT DESCRIPTION
The following listed items are components of HRVBBLHU (See
Fig. 8).
1. Stale air return from building connected to return-air duct
system.
2. Fresh air intake connected to outdoor air inlet hood.
3. Exhaust air connected to outdoor air exhaust hood.
4. Mechanical filters trap dust contained in the air.
5. Heat recovery core is either a cross-flow type for compact
models, or a counter-flow type for high efficiency models.
The core transfers heat between the 2 air streams.
6. Blowers bring in fresh air from outside and exhaust stale air
to outside.
7. Electronic control circuit ensures proper unit operation.
8. Fresh air supply from HRV connected to return air duct of
forced air system.
9. Terminal connector block for wiring wall and timer con-
trols.
10. Electrical cord connects to standard 115-v outlet.
The following listed items are components of HRVBBSVU
and HRVBBLVU (See Fig. 9 and 10).
1. Stale air return from building connected to return-air duct
system.
2. Fresh air intake connected to outdoor air inlet hood.
3. Exhaust air connected to outdoor air exhaust hood.
4. Dampers are used to control air exchange with outdoor air
during defrost mode.
5. Mechanical filters trap dust contained in the air.
6. Heat recovery core is either a cross-flow type for compact
models, or a counter-flow type for high efficiency models.
The core transfers heat between the 2 air streams.
7. Blowers bring in fresh air from outside and exhaust stale air
to outside.
8. Capacitor required for motor operation.
9. Condensation tray collects condensate from heat recovery
core.
10. Drainage tubes connect to sleeved grommets
11. Electronic control circuit ensures proper unit operation.
12. Fresh air supply from HRV connected to return air duct of
forced air system.
13. Terminal connector block for wiring wall and timer con-
trols.
14. Electrical cord connects to standard 115-v outlet.
Fig. 9—HRVBBSVU Compact Unit
A98408
4
5
10
3
2
1
11
13
7
14
12
8 9
6
Fig. 8—HRVBBLHU Conventional Horizontal Unit
A99283
4
9
10
1
2
4
6
6
8
3
7
Fig. 10—HRVBBLVU Compact
High-Efficiency Unit
A98409
1
12
3
14
2
4
6
11
13
8
9
10
7
5
—5—

Other manuals for Bryant HRVBBSVU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant HRVBBSVU and is the answer not in the manual?

Bryant HRVBBSVU Specifications

General IconGeneral
BrandBryant
ModelHRVBBSVU
CategoryFan
LanguageEnglish

Related product manuals