Electrical systems – 5000 LPE 240
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 10- 25
10.6 Parameters
Press S18 and turn S17 to on at the same time.
Press S18 until you read P= parameters.
You have now choosen P=parameters the symbol “C” on display will
be highlighted to indicate what’s currently shown on display.
Scroll to the parameter you want to change or look at by pressing the
L1 up or down.
Press S18 ones to get access to the parameter.
Set parameter value by pressing L1 up or down.
Press S18 ones to confirm change.
Turn S17 to off.
You have now completed a parameter change and the next time you
start the truck the new parameter setting will be valid.
NOTE !
Truck handling.
Modifying specific truck parameters will change the driving charac-
teristics of the truck.
Do not change any parameters without the necesarry know-how.
10.6.1 Driver parameters
Parameter Name Unit Min Max Step Std Description
1 Speed, low
Speed
% 10 100 5 100 10:low Speed
100:highest Speed
02 Speed, high
speed
% 10 100 5 100 10:low Speed
100:highest Speed.
03 Acceleration 10 100 5 75 10:low acceleration
100:full acceleration
04 Neutral speed
reduction
5 100 5 80 Defines motor speed
reduction force when
lever goes to neutral
position.
5: low reduction force
100: full reduction force
05 Logout 1min 0 20 1 20 The time it takes for the
truck to switch off when
the keypad is used. The
time counts down from
the moment the last
power-consuming unit
is used.
Value = 0 gives 4 hours.
In steps of 1