EasyManua.ls Logo

BT LPE240 - Service Indication

BT LPE240
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 9- 47
_
Service indication
Connect CAN key to X41 and start the truck
Battery status is shown and symbol “D” is lit
Press S18 to go to display mode.
See the table below.
*These are displayed by segments of three of the figures being marked (A).
Table 5: Standard PIN code assignment with the expanded
keypad
Driver profile
no.
0 1 2 3 4 5 6 7 8 9
Block 0 0000 0001 0002 0003 0000 0000 0000 0000 0000 0000
Block 1 5421 7901 1437 3731 1049 9439 7265 1322 2869 1574
Block 2 1787 4854 2907 9175 5799 1490 3031 7392 5622 5023
Block 3 4659 3174 1026 3815 6703 1179 5152 7514 5668 3215
Block 4 9197 7110 5477 3846 9491 5918 8222 6923 8139 7025
Block 5 2549 6276 9879 9658 1690 4042 5201 9807 4332 9715
Block 6 7474 4142 8620 3754 8432 8788 7430 1948 2595 8527
Block 7 1930 1482 7135 2395 7365 7092 4611 2831 4185 6067
Block 8 2876 4731 1022 5377 3257 7334 9009 7881 8843 7436
Block 9 3242 3162 5878 2828 1910 6907 2136 5730 2957 7691
Flashing symbol Data
B A speed reference value has been sent
to Curtis
C Digital inputs to Curtis and hall sensors.
* See explanation below
BC Battery voltage (V)
D Armature voltage (A)
BD Field current (A)
CD PWM (pulse width modulation) armature
in percentage
BCD Status of Curtis
A
B
C
DE

Table of Contents