9- 32 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
9.6.3 Service parameters
• Connect the CAN key to X41.
• Press and hold S18 while turning S17 to “ON” position.
• Press and hold S18 until P = parameters is displayed.
• You have now selected P = parameters and the symbol “C” is lit as
an indication of what is now shown in the display.
• Press L1 up or down and scroll to the parameter you want to change
or view.
• Press S18 once to access the parameter.
• Press L1 up or down to specify the parameter value.
• Press S18 once to confirm the change.
• Turn S17 to the off position.
You have now changed the parameter and the new setting will come
into force the next time you start the machine.
NOTE:
Truck handling
When you change specific truck parameters, the truck’s driving char-
acteristics are also changed.
Do not change any parameters unless you really know what you are
doing.
Parameter Description Unit Min. Max. Step Std. Description
10 PIN-code 0 9999 1 1
Facility for specifying up to 10
PIN codes (10 different drivers).
14 Crawling
speed
-10 10 1 0 The amount of power the mon-
itor should emit when you
reach the first speed sensor
can be specified here.
-10: low speed for the first
speed sensor.
10: high speed for the first
speed sensor
15 Non-config-
urable option
0 to 9
See “Option parameters” on page 34, Servicemanual
16 Configurable
option #1
See “Option parameters” on page 34, Servicemanual
17 Configurable
option #2
18 Configurable
option #3
19 Configurable
option #4
20 Hour meter
option
1 5 1 2 Select hour meter.
21 Battery size 1 20 1 5 Selection of battery size.
A
B
C
DE