10-  30 Service Guide  LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical systems – 5000 LPE 240
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497  723984- 2005-05-11 225553-040
Changing non-configurable options
• Ensure the truck is in parameter mode.
The parameter symbol is lit.
• Select parameter #15 using [L1].
The first set-up of sub-parameters is displayed
The next set-up of sub-parameters is displayed if you continue to acti-
vate the speed control L1. Ensure that only the relevant sub-parame-
ters are displayed.
The value of the sub-parameters is displayed after 1 second.
• Press the horn button S18. 
The parameter symbol flashes. .
• Enter the sub-parameter value by repeatedly operating the speed 
control L1 in either direction. See 
Table 6: for more information.
• Press the S18 horn button once to confirm the new setting.
The parameter symbol is lit (i.e. stops flashing).
• Switch off the truck by pressing    on the keypad.