Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497 
© BT Europe AB Service Guide  LWE180, LWE200, LPE200, LPE240 9-  41
Recommendation on parameter setting for freely 
ventilated batteries
WARNING !
The service life of the battery will be reduced if the value of parameter 
21 is set at too high a value. The standard setting of parameter 21 is 
set for normal truck handling. Other applications may require a differ
-
ent setting of parameter 21. Check that the parameter setting is the 
correct one using the instructions below.
Parameter 21 Battery size 
LWE180, LWE200, 
LPE200-6
Battery size 
LPE200-8
Less dis-
charge
Greater dis-
charge
1
2
3
4
5 260Ah - 320Ah
Standard value
6 190Ah - 250Ah
7 120Ah - 180Ah 260Ah - 320Ah
Standard value
8 190Ah - 250Ah
9 120Ah - 180Ah
10
11
12
13
14
15
16
17
18
19
20