EasyManua.ls Logo

BT LPE240 - Resetting Errors; Safety

BT LPE240
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10- 48 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical systems – 5000 LPE 240
Diagnostic and troubleshooting
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
10.9.2 Resetting errors
To reset an error turn S17 to off and then on again.
10.9.3 Safety
The regulator is a high-power component. When working on a battery
operated vehicle, necessary precautions should be taken. This
includes, but is not limited to, correct training, use of eye protectors,
avoiding use of lose-fitting clothes, removal of watches and jewellery,
and use of insulated tools only.
WARNING!
Risk of short-circuiting.
Remove all watches, jewellery and always use insulated tools only.
Error Reset when
OVERVOLTAGE Battery voltage falls below 33 V
THERMAL CUTBACK The temperature is within allowed
range
THROTTLE FAULT 1, 2 Error has been fixed
LOW BATTERY VOLTAGE When battery voltage exceeds 16 V

Table of Contents

Related product manuals