10- 48 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical systems – 5000 LPE 240
Diagnostic and troubleshooting
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
10.9.2 Resetting errors
To reset an error turn S17 to off and then on again.
10.9.3 Safety
The regulator is a high-power component. When working on a battery
operated vehicle, necessary precautions should be taken. This
includes, but is not limited to, correct training, use of eye protectors,
avoiding use of lose-fitting clothes, removal of watches and jewellery,
and use of insulated tools only.
WARNING!
Risk of short-circuiting.
Remove all watches, jewellery and always use insulated tools only.
Error Reset when
OVERVOLTAGE Battery voltage falls below 33 V
THERMAL CUTBACK The temperature is within allowed
range
THROTTLE FAULT 1, 2 Error has been fixed
LOW BATTERY VOLTAGE When battery voltage exceeds 16 V