Page 15
WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.
GAS CONNECTION
Check gas type. Use only type of gas indicated on valve rating plate. If type of gas listed on plate is
not your type of gas supply, DO NOT INSTALL.
Contact your dealer for proper model.
Always use an external regulator for all LP heaters to reduce supply tank pressure to a maximum of 13"
W.C. This is in addition to regulator furnished with heater.
WARNIN G: CONNECTION DIRECTLY TO AN UNREGULATED LP TANK CAN CAUSE
AN EXPLOSION.
The normal gas connection is 3/8” N.P.T. made at left side (facing front of appliance) of appliance. If
a right side connection is desired, connecting pipe may be led under rear of burner base to terminate at
right side for connection to inlet of valve.
NOTE: The connecting pipe must be internally tinned copper tubing for use with natural gas. Test for
leaks using a solution of soap and water after completing connection. DO NOT USE OPEN FLAME.
WARNING: Installation and repairs should be performed by a qualified service person. The
appliance should be inspected before use and at least annually by a professional service person.
More frequent cleaning may be required due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments, burners and circulating air passageways of
appliance be kept clean.