MODEL 36
MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE
OR WITH AN OPTIONAL WOODEN SURROUND
WARNIN G: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to
section “ Producing Adequate Air For Combustion And Ventilation” page 11.
This appliance may be installed in an aftermarket, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
VENT-FREE
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance is intended for supplemental heating.
MANUFACTURED BY NEW BUCK CORPORATION
200 ETHAN ALLEN DRIVE,
SPRUCE PINE, N.C. 28777
www.buckstove.com Revised January 2013
Question and Answer IconNeed help?

Do you have a question about the BuckMaster 36 and is the answer not in the manual?

Summary

Safety Information Warnings

Installation Restrictions and Prohibitions

Details specific locations and conditions where the heater must never be installed.

Gas Type and Model Compliance

Specifies correct gas type usage and compliance with industry standards.

General Safety Precautions

Provides essential safety warnings and general guidelines for operating the appliance.

Operational Safety and Handling

Gas Leak Emergency Procedures

Outlines immediate steps to take if a gas leak is detected to ensure safety.

Appliance and Log Handling Safety

Covers safe operation, maintenance, and handling of the heater and its components.

Continued Safety and Installation Guidelines

Burner Operation and Material Warnings

Addresses safe operation, preventing soot, and avoiding hazardous materials near the appliance.

Installation Clearances and Precautions

Covers safe installation clearances, and general user precautions for safe operation.

INSTALLATION (ZC) (WS)

Choosing Fireplace Location

Guidance on selecting an optimal and safe location for fireplace installation.

Gas Lines and Drafts Precautions

Information on gas line installation requirements and avoiding areas with high drafts.

FIREPLACE AND FRAMING DIMENSIONS

FIREPLACE CLEARANCES (ZC)

Sidewall, Ceiling, and Mantel Clearances

Specifies minimum required distances from fireplace opening to walls, ceiling, and mantels.

Floor Clearances and Combustible Material Rules

Details floor clearance requirements and rules for combustible materials around the fireplace.

INSTALLING FIREBOX (ZC)

Firebox Framing and Installation Steps

Steps for framing, installing, leveling, and securing the firebox into the opening.

PRODUCING ADEQUATE AIR FOR COMBUSTION AND VENTILATION

Unusually Tight Construction Definition

Defines 'unusually tight construction' based on air exchange rates and building sealing.

Combustion Air Requirements and Warnings

Details the necessity of adequate air for combustion and ventilation, especially in tight constructions.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Calculating Space Volume and BTU Support

Worksheet to calculate room volume and its capacity to support appliance BTU input.

Calculating Total Appliance BTU Load

Instructions to sum the BTU/Hr of all fuel-burning appliances in the space.

Comparing BTU Load to Space Capacity

Compares appliance BTU load to space capacity to determine ventilation needs.

AIR FOR COMBUSTION AND VENTILATION FROM INSIDE BUILDING

Ventilation Options from Adjoining Spaces

Provides methods for supplying combustion air from adjoining rooms or spaces.

AIR FOR COMBUSTION AND VENTILATION FROM OUTDOORS

Ventilation Options from Outdoors

Details how to provide combustion air directly from outdoors using grills or ducts.

GAS CONNECTION

Gas Type and Connection Procedure

Ensures correct gas type connection and highlights safety warnings for installation.

LP Gas Tank Connection Warning

Specific warning regarding the dangers of connecting directly to an unregulated LP gas tank.

GAS PRESSURE CHECK

Pressure Check Points and Procedures

Details where and how to check gas inlet and manifold pressures for proper operation.

Bleeding Air from Gas Lines

Instructions on how to remove air from the gas lines during initial installation.

CR3329 CERAMIC LOG SET PLACEMENT

Log Placement Diagram and Warnings

Visual guide and critical warnings for correctly positioning the CR3329 ceramic log set.

E.S.B. LOG SET PLACEMENT FOR MODEL 36

E.S.B. Log Set Placement Instructions

Detailed steps and warnings for properly installing the E.S.B. log set on the heater.

Glowing Embers Installation

Guidance on applying the glowing embers material to the burner pan.

LIGHTING INSTRUCTIONS MILLIVOLT VALVE (ITT)

Pre-Lighting Safety Checks

Essential safety checks and procedures to follow before attempting to light the pilot or burner.

LIGHTING INSTRUCTIONS (ITT)

Pilot Lighting Procedure

Step-by-step guide for safely lighting the pilot light on the ITT millivolt valve system.

Main Burner Ignition

Instructions for igniting the main burner after the pilot light is successfully lit.

SHUTTING OFF UNIT

THERMOSTAT CONTROL OPERATION

Thermostat Operation Mode

Explains how the thermostat adjusts gas flow to regulate room temperature.

MANUAL LIGHTING PROCEDURE

Manual Pilot Lighting with Match

Procedure for manually lighting the pilot using a match when the piezo igniter fails.

LIGHTING INSTRUCTION MODULATING OR MANUAL VALVE (SIT)

Pre-Lighting Safety Checks (SIT Valve)

Essential safety checks and procedures for SIT modulating or manual valves before lighting.

LIGHTING INSTRUCTIONS (SIT Valve)

SIT Valve Pilot Lighting Procedure

Step-by-step guide for safely lighting the pilot light on the SIT modulating or manual valve.

SHUTTING OFF UNIT

THERMOSTAT CONTROL OPERATION

Thermostat Functionality

Explains how the thermostat senses room temperature and adjusts burner output.

MANUAL LIGHTING PROCEDURE

Manual Pilot Lighting Procedure

Procedure for manually lighting the pilot light using a match and lighter rod.

LIGHTING INSTRUCTIONS SIT-MILLIVOLT VALVE

Pre-Lighting Safety Checks (SIT Millivolt)

Essential safety checks and procedures for SIT millivolt valves before lighting.

LIGHTING INSTRUCTIONS (SIT Millivolt Valve)

SIT Millivolt Valve Pilot Lighting

Step-by-step guide for safely lighting the pilot on the SIT millivolt valve system.

SHUTTING OFF UNIT

MANUAL LIGHTING PROCEDURE

Manual Pilot Lighting Steps

Procedure for manually lighting the pilot light using a match and lighter rod.

FLAME CHECK

Flame Appearance and Characteristics

Details the expected appearance, color, and height of flames for proper operation.

WIRING DIAGRAM

ROOM BLOWER INSTALLATION AND OPERATION INSTRUCTIONS

Blower Motor Installation Procedure

Step-by-step guide for removing, replacing, and installing the room air blower motor.

IMPORTANT SAFEGUARDS

General Heater and Log Safety

Crucial safety guidelines for operating the heater and handling its ceramic fiber components.

Cleaning Precautions and Warnings

Safety instructions and warnings related to cleaning the heater and its logs.

TROUBLESHOOTING

Igniter Spark and Pilot Ignition Issues

Troubleshooting guide for problems related to igniter spark and pilot ignition.

TROUBLESHOOTING (Continued)

Pilot Light Out Issues

Addresses common problems where the pilot light goes out after ignition.

Burner Ignition and Combustion Problems

Troubleshooting for issues like burner not lighting, delayed ignition, or backfiring.

TROUBLESHOOTING (Continued)

Odor and Noise Troubleshooting

Addresses issues causing odors, whistling noise, or clinking/ticking sounds.

WARNING: IF YOU SMELL GAS:

Gas Leak and Odor Detection

Provides warnings about gas leaks and troubleshooting for detected gas odors.

SERVICING

REPAIR PARTS

REPLACEMENT PARTS ITT VALVE 19 GL BASE

ITT Valve Replacement Parts List

Detailed list of part numbers for replacement components of the ITT valve system.

REPLACEMENT PARTS SIT MODULATING VALVE OR SIT MANUAL VALVE 19 GL BASE

SIT Modulating;Manual Valve Parts

List of replacement part numbers for SIT modulating and manual valve systems.

REPLACEMENT PARTS SIT MILLIVOLT VALVE 19 GL BASE

SIT Millivolt Valve Replacement Parts

List of replacement part numbers for the SIT millivolt valve system.

REPLACEMENT PARTS FOR SIT MILLIVOLT VALVE ESB. BASE

ESB Base Millivolt Valve Parts

List of replacement parts for the SIT Millivolt Valve ESB Base.

NEW BUCK CORPORATION LIMITED WARRANTY

Two-Year Limited Warranty Terms

Details the terms and conditions of the two-year limited warranty for the product.

Warranty Exclusions and Limitations

Outlines what the warranty does not cover and legal limitations on liability.

OWNER REGISTRATION

BuckMaster 36 Specifications

General IconGeneral
BrandBuckMaster
Model36
CategoryIndoor Fireplace
LanguageEnglish