4
Tank Assembly
Logalux SM300/1 - SM400/1 - Technical specifications are subject to change without prior notice.
12
4 Tank Assembly
4.1 SM300/1 Placement and Installation
4.1.1 Installation of tank feet
V Place top foam material on the floor [1].
V Carefully place the solar tank on its side on top of the
foam material.
V Remove the tank support bolts M10x30 from the Styro-
foam packaging and screw into the bottom of the tank
[2].
V Put solar tank straight-up and level by adjusting the
tank bolts [2].
Fig. 8 Installation of tank bolts
1 Foam packaging material
2 Tank bolts
4.1.2 Installation of tank aquastat or temperature
sensor
V To measure and secure the DHW water temperature
an installed temperature sensor or aquastat on the
DHW tank is reqiured.
Danger: Due to electricity.
V Electrically disconnect the system.
For DHW temperature control, one can
use an aquastat or tank sensor depending
on the selected control strategy.
Follow the directions supplied by the manu-
facturer of the aquastat or tank sensor re-
garding electrical wiring connections.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Buderus Logalux SM400/1 and is the answer not in the manual?

Buderus Logalux SM400/1 Specifications

General IconGeneral
BrandBuderus
ModelLogalux SM400/1
CategoryWater Heater
LanguageEnglish

Related product manuals