3
Moving the boiler
Logano G234X - Technical specifications are subject to change without prior notice.
9
3 Moving the boiler
This section details how to move the boiler safely.
Moving the boiler with hand truck
B Position transport equipment (e.g. trolley) at the back
of the boiler.
B Secure packaged boiler to the hand truck.
B Move the packaged boiler to the installation location.
Fig. 4 Moving boiler with trolley
B Remove the straps and the cardboard packaging.
B Loosen the retaining screws.
B Lift the boiler at the sides and slide to the edge of the
pallet.
B Place a pipe under the boiler and roll it on additional
pipes to the installation location.
B Place the boiler in its final position.
Fig. 5 Moving the boiler
NOTICE: Risk of system damage from
impact shocks!
Fragile components could be damaged.
B Observe the transport instructions on the
packaging.
NOTICE: System damage due to improper
transport!
B Protect sheet metal parts, flue gas pipe,
burner, and control unit during transport.
B Do not lift the boiler using these
components.
Dispose of packaging in an environmentally
responsible manner.
WARNING: Risk of injury if load is
inadequately secured during transportation.
B Use suitable means of transportation, e.g.
a trolley with strap.
B When transporting, secure the boiler to
prevent it falling.

Table of Contents

Other manuals for Buderus Logano G234X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Buderus Logano G234X and is the answer not in the manual?

Buderus Logano G234X Specifications

General IconGeneral
BrandBuderus
ModelLogano G234X
CategoryBoiler
LanguageEnglish

Related product manuals