Troubleshooting | 11
0870169526_KB_KC0010-0016E_A0004_IM_en 19 / 24
The machine runs too hot. Insufficient cooling. • Remove dust and dirt
from the machine.
• Check the cooling fan.
Ambient temperature too
high.
• Observe the permitted
ambient temperature.
Oil level too low. • Top up oil.
The exhaust filters (EF) are
partially clogged.
• Replace the exhaust filters
(EF).
The machine fumes or ex-
pels oil droplets through the
gas discharge.
The exhaust filters (EF) are
partially clogged.
• Replace the exhaust filters
(EF).
An exhaust filter (EF) with o-
ring is not fitted properly.
• Ensure the correct posi-
tion of the exhaust filters
(EF) and the o-rings.
The oil is black. Oil change intervals are too
long.
• Flush the machine (con-
tact Busch).
The inlet filter (optional) is
defective.
• Replace the inlet filter.
The machine runs too hot. • See problem "The ma-
chine runs too hot".
The oil is emulsified. The machine sucked in li-
quids or significant amounts
of vapour.
• Flush the machine (con-
tact Busch).
• Clean the filter of the gas
ballast valve (GB).
• Modify the operational
mode (see Conveying
Condensable Vapours
[
►12]).
For the solution of problems not mentioned in the troubleshooting chart contact your