Commissioning | 6
0870569132_SV_SD_DC1010-1040C_-0005_IM_en 11 / 24
6 Commissioning
NOTICE
Lubricating a dry running machine (compression chamber).
Risk of damage to the machine!
Do not lubricate the compression chamber of the machine with oil or grease.
CAUTION
During operation the surface of the machine may reach temperatures of more than
70°C.
Risk of burns!
Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended
periods:
Make sure that ear protection is being used.
Make sure that the installation conditions (see Installation Conditions [7]) are met.
Switch on the machine.
Make sure that the maximum permissible number of starts does not exceed 12 starts
per hour. Those starts should be spread within the hour.
Make sure that the operating conditions comply with the Technical Data [22].
As soon as the machine is operated under normal operating conditions:
Measure the motor current and record it as reference for future maintenance and
troubleshooting work.