GasAlertMicroClip
Quick Reference Guide
Specifications
Verify that the battery PCB is in the same position
as when the rear shell was removed (refer back to
step #2).
Instrument dimensions: 10.75 x 6.00 x 2.73 cm
(4.2 x 2.4 x 1.1 in.)
Weight: 160 g (5.7 oz.)
Visually inspect the battery to ensure that it has
not been damaged before replacing the rear shell.
Operating temperature: -20°C to +58°C (-4°F to +136°F)
+50°C to +58°C is certified by CSA-International on the
combustible sensor with ±5% accuracy
Ensure the rib on the interior of the rear shell fits
between the battery pack and the PCB (as shown
in the following figure).
Storage temperature: -40°C to +50°C (-40°F to +122°F)
Operating humidity: 0% to 95% relative humidity
(non-condensing)
Alarm setpoints: May vary by region and are user-settable
Detection range:
H
2
S: 0 – 100 ppm (1 / 0.1 ppm increments)
H
2
S: 0 – 200 ppm (1 ppm increments)
CO: 0 – 500 ppm (1 ppm increments)
CO: 0 – 1000 ppm (1 ppm increments)
O
2
: 0 – 30.0% vol. (0.1% vol. increments)
Combustible (LEL): 0 – 100% (1% LEL increments) or
0 – 5.0% v/v methane
Sensor type:
H
2
S, CO, O
2
: Single plug-in electrochemical cell
Combustibles: Plug-in catalytic bead
14