2. SETTING THE WATER HARDNESS
The display default is 300 (typical hardness level), which indicates a setting suitable for
hard water with a hardness value of 300 parts per million of hardness minerals. Use the
keys to adjust the setting to match that of the one you obtained / identified
earlier. See page 9 for details Press the key once to set the hardness value and
move the display into the Set Regeneration Time mode.
.
1. SETTING THE TIME OF DAY
The first two digits (00) of the display will flash prompting the installer to set the time.
The time is adjusted by using the keys. Pressing the key once enters the
hours. The minutes can then be set by using the keys. Pressing the key once
enters the minutes and moves the display into the Set Hardness mode.
PROGRAMMING PROCEDURE
10
P
A
RT WO
T
11
3. SETTING THE RECHARGE TIME
To operate effectively, your water softener needs to regenerate periodically (dependent on
the hardness of the supply and amount of water used). The default time of day when this
is to occur is 2.00am. To alter this setting use the keys.
Pressing the key once will return the display to the Normal Operation mode.
Programming is now complete and no further adjustment of the water softener is required.
Remember to check the salt level in the brine cabinet weekly.
PTTO
AR W
4. Charge Bar
Having set the display on the control facia, you will notice that during normal operation
there is a charge bar running along the bottom of the display. This charge bar shows the
percentage of water softener capacity remaining since the last regeneration. Immediately
following a regeneration, the charge bar returns to 100%.
6. Power Loss
The AMECS system will maintain the individual programming parameters of the water
softener for up to 72 hours.
If the power cut lasts longer than 72 hrs, the control will flash "00:00" when power is
returned to the control. The unit will continue to keep time from the moment power is
restored. In this situation the time of day will need to be reset.
00:00
SET
TIME
+ -
+ -
00:00
+ -
Hardness
set
300
+ -
Recharge time
Set
02:00
5. Resetting the display during normal operation.
If the time is to be adjusted during normal operation, press any key to illuminate the
display, press the key once. The display will flash and indicate present time. Using the
keys will alter the time as described previously on page 10.
+ -
7. Flow Indicator
During normal operation, a flow indicator will flash on the display at a rate of one litre per
pulse when water is passing through the softener.
8. Cleaning
Your water softener may be cleaned using a damp cloth and a mild detergent. Do not use
bleaches, solvents or spirits as they may damage the surfaces.