Notice technique ADOUCISSEUR A27-A6X - Manual SOFTENER A27-A6X code P0011144 - Rev 0 - 29/02/2016
Advanced maintenance
Here are the interventions to be done at a minimum level in order to keep a lasting performance and
to be performed by a professional, preferably under a maintenance contract.
Maintenance guidelines Frequency Wear part?
Overall checkup
• Test the regeneration
• Check the setting
• Check the internal components in the
hydraulic block, and cleaning
• Salt tank cleaning
Once a yea
Inlet grid replacement Once a yea Yes
Internal component replacement Every 2 years Yes
Turbine replacement Every 3 years Yes
Hydro-ejector replacement Every 3 years
Brining system replacement Every 3 years
Replacement of electrically driven com-
ponents
• Solenoid valves
• Chlorination cell & cable
• Proportional regeneration unit
Every 5 years
Inlet and outlet fl exible hoses replacement
To be checked once
a year