Contenu du colis et caractéristiques de votre adoucisseur
Scope of delivery and softener features
Voir chapitre INSTALLATION - VUE D'ENSEMBLE de la notice (mêmes numéros de repères). Fournis de
série : l'adoucisseur (repère 1 ) avec son coffret de commande (2) alimenté électriquement (6), son bac à sel
(3) surmonté de la trappe (4) et contenant le régulateur à saumure (5).
See chapter INSTALLATION - OVERVIEWof the instruction manual (same item numbers).
Supplied:
the softener (item 1) with its controller unit (2) and power supply (6), its salt tank (3) covered by the lid (4) and
holding the brine valve (5).
INITIAL
Réf. S2011 097
DUAL
Réf. S2011 099
INTEGRAL
Réf. S20111 01
BIO 22
Réf. S20111 90
BIO 30
Réf. S2011 200
Préfiltre (7)
Prefilter
2
Evacuations
& siphon
(8 - 1 0 - 11 )
Bypass (1 2)
H
L
P
Filtre in tég dans l'adoucisseur
Filter included in the softener
Non fourni
Not supplied
Largeur (
length
) L = 41 cm
Hauteur (
height
) H = 11 0 cm
Profondeur (
depth
) P = 53,5 cm
Monobloc avec deux réductions
Monobloc with two reduction fittings
A assembler
To be assembled
Flexibles entrée / sortie (1 3)
IN & OUTflexible hoses
Connexion 3/4'', longueur 80 cm
3/4'' connection, 80 cm long
Volume de résine
Resin volume
22 litres
22 litres
22 litres
30 litres
Stockage de sel
Salt storage
1 25 kg 1 25 kg 1 25 kg
1 20 kg
Evacuation vanne (8) - longueur 1 ,6 m - diamètre intérieur 1 2 mm
Valve evacuation (8) - 1.6 m long - inner diameter 12 mm
Trop-plein bac à sel (1 0) - longueur 1 ,6 m - diamètre intérieur 1 5 mm
Salt tank overflow (10) - 1.6 m long - inner diameter 15 mm
S9012468 - REV 201 6-09-06
Egalement fourni : tube d'aspiration de saumure (9) - longueur 2 m - diamètre intérieur 6 mm
Also supplied: brining tube (9) - 2 m long - innerdiameter 6 mm
4
3
6
Régulateur à saumure (5)
non représenté.
Brine valve (5) not drawn.
Réglage flotteur*
Float height*
11 0 mm
11 0 mm
11 0 mm
1 70 mm
* Régler le régulateur à saumure (5), chapitre INSTALLATION
* Set the brine valve (5), chapter INSTALLATION PROCEDURE
1
CONNEXIONS DES CÂBLES
(Cables connections)
Sonde de chloration (si applicable)
Chlorination cell (ifapplicable)
Compteur
Water meter
Marron
(braun)
Bleu
(blue)
Bleu
(blue)
Noir
(black)
Rouge
(red)
Bleu
(blue)
INITIAL DUAL
INTEGRAL / BIO 22
BIO 30
IMPORTANT :
Modèles
DUAL
INTEGRAL
BIO 22
BIO 30
Filtre intégré
dans l'adoucisseur
Préfiltre inutile
Filter included in the softener
for DUAL, INTEGRAL, BIO 22, BIO30
.
No prefilter required
Raccorder également le
transformateur
à l'arrière de la carte électronique.

Questions and Answers

  • J
    Joseph MooreAug 16, 2025
    What to do if the BWT INTEGRAL Water Dispenser delivers water that doesn't seem softened anymore?
    • C
      caleb29Aug 16, 2025
      If the water from your BWT Water Dispenser isn't softened, measure the residual hardness. Then: 1. Ensure the bypass is open to direct water to the softener. 2. Check and refill the salt tank if needed. 3. Replace the filter element if it's clogged. 4. Redo the blending procedure.
  • M
    michaelorozcoAug 19, 2025
    Why does my BWT INTEGRAL Water Dispenser display 'CHECK' and 'SALT' alternately?
    • T
      Taylor HensonAug 19, 2025
      The 'CHECK' and 'SALT' message on your BWT Water Dispenser indicates that the salt tank is empty or the device has detected a regeneration flaw. Refill the tank with salt. If the message persists, it might indicate a more complex issue.
  • M
    Megan OrtegaAug 22, 2025
    What to do if there's water overflowing from the salt tank of my BWT INTEGRAL?
    • J
      Jordan PorterAug 22, 2025
      If your BWT Water Dispenser's salt tank is overflowing, it's likely due to a brining chain malfunction or leak. Check the connection between the bring tube and the brine valve. If the overflow continues, it suggests a more significant problem.
  • J
    John KellyAug 26, 2025
    What to do if water flows through the evacuation tube of my BWT Water Dispenser?
    • S
      stacey73Aug 26, 2025
      Water flowing through the BWT Water Dispenser's evacuation tube is normal during regeneration, indicated by 'ASPI' or 'RINCE' on the display. If these aren't displayed, it indicates a failure of internal components.
  • W
    wbraunAug 28, 2025
    How to correct the time on my BWT INTEGRAL Water Dispenser?
    • A
      Andrew MooreAug 28, 2025
      The time may be incorrect on your BWT Water Dispenser due to a seasonal time change or a power cut that affected data recovery. Reset the time in the settings. If the issue continues, it could indicate a battery problem.
  • J
    Jessica HowardAug 31, 2025
    What to do if there is no display on my BWT INTEGRAL?
    • R
      Renee HunterAug 31, 2025
      If your BWT Water Dispenser has no display, first check if the power is on. Ensure the device is properly plugged into a working power outlet. If the outlet works, the issue may be an electrical or electronic failure.
  • E
    Elizabeth HernandezSep 3, 2025
    What to do if my BWT INTEGRAL Water Dispenser shows 'CHECK' and 'SALT'?
    • P
      Phillip WalkerSep 3, 2025
      If the BWT Water Dispenser displays 'CHECK' and 'SALT' alternately, it indicates that the salt level in the tank is low or the device has detected a regeneration error. First, refill the salt tank. If the message persists after refilling, it's recommended to contact technical support for further assistance.
  • T
    tina53Sep 6, 2025
    Why is my BWT INTEGRAL Water Dispenser not softening water anymore?
    • G
      gwoodSep 6, 2025
      If the water from your BWT Water Dispenser is no longer softened, indicated by limescale returning, several factors could be at play. Measure the residual hardness, and then check the following: Ensure the bypass is correctly positioned to direct water to the softener. Verify and refill the salt tank if it's low. Inspect the filter for clogs and replace it if necessary. Redo the blending procedure as described in the commissioning chapter. If the issue persists after these steps, contact technical support.
  • D
    deannamccoySep 9, 2025
    Why is water flowing through the evacuation tube of my BWT INTEGRAL Water Dispenser?
    • J
      Joshua GatesSep 9, 2025
      If you notice water flowing through the evacuation tube of your BWT Water Dispenser, it could be due to a normal regeneration process. Check if the display shows 'REGE 1', 'REGE 2', or 'REGE 3'. If the device is not regenerating, contact technical support, as it may indicate an internal component failure.
  • A
    Amanda LowerySep 12, 2025
    What to do if there is water overflowing from the salt tank of my BWT INTEGRAL?
    • V
      velezleslieSep 12, 2025
      If there's water overflowing from the salt tank of your BWT Water Dispenser, it suggests the brining chain isn't closing properly or is leaking. Examine the connection between the brine tube and the brine valve. If the overflow continues, contact technical support for assistance.

Summary

Requirements for Use

General Usage and Location Guidelines

Covers device use, unpacking, proper location, and required interventions by authorized personnel.

Plumbing and Electrical Safety Precautions

Guidelines for water connections, pressure reduction, and electrical safety compliance.

Installation Procedure

Hydraulic Block and Pressure Checks

Steps for tightening the hydraulic block and verifying network water pressure.

Power Outlet and Pre-filter Installation

Ensuring correct power outlet connection and installing the upstream pre-filter.

Softener Placement and Brine Valve Assembly

Positioning the softener and correctly assembling and connecting the brine valve.

Connecting Hydraulic and Electrical Blocks

Connecting inlet/outlet hoses, drain tubes, and optional chlorination cell.

Drain Outlets and Air Purging

Connecting drain outlets, siphon, and purging air from the system before operation.

Setting the Softener

Commissioning the Softener

Softener Operation Guide

Routine and Advanced Maintenance

Troubleshooting Common Issues

BWT INTEGRAL Specifications

General IconGeneral
Number of Filtration Stages5
Voltage220-240V
Frequency50/60 Hz
Water TypesHot, Cold, Ambient
Hot Water Temperature85-95°C
Power Consumption500 W