Lightning Series Fiber Laser User Manual
1
1.
Introduction
Welcome to use the CW fiber laser system produced by BWT. This user manual is applicable
to Lightning series fiber lasers, and the product model cover BFL-CW500, BFL-CW1000,
BFL-CW1500, BFL-CW2000, BFL-CW3000 and BFL-CW6000.
This manual contains safety instructions, product description, installation, usage,
maintenance as well as troubling. Please read this manual carefully before installing and operating
the products and also strictly follow the safety instructions in this manual, otherwise personal
injury or equipment damage may occur.
The copyright of this manual belongs to the company, and no organization or individual may
copy or transmit the content of this manual in any form without the permission of the company.
2. Safety Instructions
2.1. Laser Safety Level
This product is a Class 4 laser product. It outputs a high-power invisible laser beam with a
wavelength of 1080±10nm. It will cause damage to the eyes or skin which is directly or indirectly
exposed to this strong laser, and may also cause on-site fire. Therefore, please strictly follow the
EU EN60825-1:2014 standard, every operator or anyone who close to the laser must be aware of
these special hazards, wear wavelength-matched and certified laser safety glasses, and take
adequate safety precautions.
There is a safety risk, which may cause serious personal injury or even
endanger life.
2.2. Security Precautions
Alarm and warning of possible hazards to installation and operating
personnel.
Self-locking, interlocking,
alarm
Built-in safety control sensors monitoring temperature, current and
voltage, optical path, QBH, etc., to realize automatic safety and
self-locking.
It can be connected to chiller and other safety interlock signals for
external switching interlock connection control of the product.
External Communication
Security Control
The communication port can be used to realize external safety
emergency stop control.