xGenConnect Installation and Programming Guide 55
Default Number
Default Name
Zone Attribute
Siren Attribute
Keypad Sounder
Report Delay
No Keypad Display
Momentary Switch
Zone Inhibit
Swinger Shutdown
12
Event Only
Event Only
Silent
N
N
Y
N
N
N
13
Momentary Key Switch
Keyswitch
Silent
N
N
N
Y
N
N
14
Latching Key Switch
Keyswitch
Silent
N
N
N
N
N
N
15
CO Detector
Instant
Four Pulse
Y
N
N
N
N
N
16
Exit Terminate
Event Only
Silent
N
N
N
N
N
N
17
Holdup
Holdup Delay
Silent
N
N
N
N
N
N
18
24 Hour Local Sounder
Instant
Silent
Y
N
N
N
N
N
19
Fire Reporting Only
Fire
Silent
N
N
Y
N
N
N
Zone Options Table
Zone Options
Zone
Reporting
Zone
Contact
Options
Default Number
Default Name
Bypassed Stay Mode
Forced Arm Enabled
Bypass
Cross Zone
EOL
Automatic Zone Test
Night Mode
Zone Inactivity Test
Follow Any Armed Partition
Final Set Door
Single EOL
Delayed in Stay
Fire Reporting Only
Alarms
Alarm Restores
Bypass
-Unbypass
Zone Lost
-Low Battery
Zone Trouble and Restore
Normally Open
Fast Loop
Zone Report Event
1
Bypass
Y
Y
Y
Y
Y
Y
Y
130:BA
2
Bypass Stay
Y
Y
Y
Y
Y
Y
Y
Y
Y
132:BA
3
Bypass
Forced Arm
Y
Y
Y
Y
Y
Y
Y
Y
130:BA
4
Bypass Cross
Zone
Y
Y
Y
Y
Y
Y
Y
Y
130:BA
5
Fire
Y
Y
Y
Y
Y
Y
Y
110:FA
6
Panic
Y
Y
Y
Y
Y
Y
Y
120:PA
7
Silent Panic
Y
Y
Y
Y
Y
Y
122:HA
8
Normally Open
no EOL
Y
Y
Y
Y
Y
Y
Y
130:BA
9
Normally
Closed no EOL
Y
Y
Y
Y
Y
Y
130:BA
10
Gas Detected
Y
Y
Y
Y
Y
Y
151:GA
11
High Temp
Y
Y
Y
Y
Y
Y
158:KA

Table of Contents