EasyManua.ls Logo

Cafection Encore 29 - Required Clearances; Brewer Specifications

Cafection Encore 29
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN1805CMINSA Rev. 5 2021-10
17
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL - Encore 29
Initial Setup
4.1.5 Clearance
Unit Clearances Allowance for
Height 29 1/4" 32" Opening top lid.
Width 22" 32" Accessing lock (right side) and opening door (left side).
Depth 24 1/2" 23 3/4" Minimum countertop depth
Back
Clearance
1 1/4" Clearance for water hookup, hoses and adequate air
circulation.
See Annex1 for waste chute positioning.
See Annex2 for a diagram illustrating required clearance.
4.2 Brewer Specifications
4.2.1 Hopper & Canister Capacities
Whole bean hopper, left section ............. 4.2 lbs (1.9kg)
Whole bean hopper, middle section ....... 3.4 lbs (1.5kg)
Whole bean hopper, right section ........... 2.0 lbs (0.9kg)
Soluble milk ........................................... 1.2 lbs (0.6kg)
Soluble hot chocolate ............................ 3.7 lbs (1.7kg)
Soluble vanilla powder ........................... 3.0 lbs (1.4kg)
4.2.2 Water Tank
Capacity ................................................ 0.74 gallons (2.8L)
Water valves .......................................... 5 simple valves
Heating element ..................................... 1250 watts
4.2.3 Electrical Specifications (Brewer Consumption)
120V AC
12A
60Hz