2012 Portable Spa
LTR20121001, Rev. A
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
9
OE9905 P4 Circuit Board Connection
Two Services
One Service
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J100
J
2
6
J53
J53
J99
J99
J97
J97
W
1
5
J27
J2
J2
J27
J32
J32
J5
5
J
9
0
J1
T1
J56
J
60
J
3
3
3
J41
J41
J45
J45
J2
W1
F4
W2
J
8
1
J31
J31
J
12
J30
J30
J
28
J
2
3
J98
J54
J54
J54
J54
J
79
J
95
J
94
J14
J14
J
5
7
J
9
6
J
9
3
F6
F
7
K7
K6
K
8
FU
S
E T30A 480V
F
US
E F10A 250V
F
U
S
E T30A 480V
J
5
9
J
5
8
J
5
K3
W
4
K2
F5
J3
J
4
F
2
F
US
E T0.3A
240
V
K4
K11
K10
K9
K1
J
9
NG
W3
BALBOA INSTRUMENTS, INC.
GL2000TC MACH 3
P
/
N 22898 REV
D
CO
PYRI
G
HT 2006
MADE IN
U
.
S
.A
.
J
1
3
J
1
5
J
17
J
82
J
2
2
J
24
EXT RELAY
J
6
EXT 2S P3
AUX F
ALA
R
M
S
EN
A
VA
C
S
EN
B
J8
3
J
9
1
C
F
G
J
17
T
S
T
S
WIT
C
HBANK A
S
WIT
C
HBANK B
F
USE F3A 250V
ADC
M
MAIN
PAN
E
L
M
AI
N
PANEL
MAIN
P
AN
E
L
AU
X
P
AN
E
L
A
UX
PAN
EL
R
EMOTE
J69
J
20
J71 J72
J70J1
0
J
39
F1
H
T
R
H
2
HTR1
H
EXT I
/O
J36
J
8
Ozone
Configuration
Settings
Enabled
RTC
Enabled
A.V.
Spa
Light
Blower
Use X-P CE or X-P231 CE
Expander for Pump 3 1-Speed
2-Spd P1
3.0 kW
3.0kW
Heater rated @ 230V
J8 must be Jumpered
DIP Switch A2 can be ON.
DIP Switch A3 and A4 must be OFF.
DIP Switch A11 must be ON.
O
N
1
2
3 4
5
6
7
8 9 10 11 12
GREEN/
YELLOW
(Ground)
BLUE (Neutral)
BROWN (Hot)
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
1 x 32 Amp
3 Wires (1 Line + 1 Neutral + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
Brown - NEUTRAL
Black - HOT
Yellow - GROUND
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J100
J
2
6
J53
J53
J99
J99
J97
J97
W
1
5
J27
J2
J2
J27
J32
J32
J5
5
J
9
0
J1
T1
J56
J
60
J
3
3
3
J41
J41
J45
J45
J2
W1
F4
W2
J
8
1
J31
J31
J
12
J30
J30
J
28
J
2
3
J98
J54
J54
J54
J54
J
79
J
95
J
94
J14
J14
J
5
7
J
9
6
J
9
3
F6
F
7
K7
K6
K
8
FU
S
E T30A 480V
F
US
E F10A 250V
F
U
S
E T30A 480V
J
5
9
J
5
8
J
5
K3
W
4
K2
F5
J3
J
4
F
2
F
US
E T0.3A
240
V
K4
K11
K10
K9
K1
J
9
NG
W3
BALBOA INSTRUMENTS, INC.
GL2000TC MACH 3
P
/
N 22898 REV
D
CO
PYRI
G
HT 2006
MADE IN
U
.
S
.A
.
J
1
3
J
1
5
J
17
J
82
J
2
2
J
24
EXT RELAY
J
6
EXT 2S P3
AUX F
ALA
R
M
S
EN
A
VA
C
S
EN
B
J8
3
J
9
1
C
F
G
J
17
T
S
T
S
WIT
C
HBANK A
S
WIT
C
HBANK B
F
USE F3A 250V
ADC
M
MAIN
PAN
E
L
M
AI
N
PANEL
MAIN
P
AN
E
L
AU
X
P
AN
E
L
A
UX
PAN
EL
R
EMOTE
J69
J
20
J71 J72
J70J1
0
J
39
F1
H
T
R
H
2
HTR1
H
EXT I
/O
J36
J
8
Ozone
Configuration
Settings
Enabled
RTC
Enabled
A.V.
Spa
Light
Blower
Use X-P CE or X-P231 CE
Expander for Pump 3 1-Speed
2-Spd P1
3.0 kW
3.0kW
Heater rated @ 230V
J8 must be Jumpered
J1
J3
J1
J3
DIP Switch A2 can be ON.
DIP Switch A3 and A4 must be OFF.
DIP Switch A11 must be ON.
O
N
1
2
3 4
5
6
7
8 9
10
11
12
GREEN/
YELLOW
(Ground)
GREEN/
YELLOW
(Ground)
BLUE (Neutral)
BLUE (Neutral)
BROWN (Hot)
BROWN
(Hot)
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
1 x 32 Amp
3 Wires (1 Line + 1 Neutral + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
Service 1:
Brown - NEUTRAL
Black - HOT
Yellow - GROUND
Service 2:
Brown - NEUTRAL
Black - HOT
Yellow - GROUND