MX Series 16
Output Parameter MX30 MX45 MX60 MX90 MX135
V Lo: 300 A
V Hi: 150 A
V Lo: 600 A
V Hi: 300 A
V Lo: 900 A
V Hi: 450 A
Frequency
Range: Standard: 16 Hz - 819.0 Hz (for –HV option range, 45 Hz – 819.0 Hz)
-LF option: 16 Hz - 500.0 Hz
-HF option: 16 Hz – 905 Hz
Resolution: 0.01 Hz from 16.00 to 81.91 Hz
0.1 Hz from 82.0 to 819.0 Hz
Accuracy: ± 0.01 %
±0.25 % for –FC option
Phase (3 phase mode)
Range: Phase B/C relative to phase A
0.0 to 360.0°
Resolution: 0.1°
Accuracy: 16 Hz - 100 Hz: < 1.5°
100 Hz - 500 Hz: < 2°
> 500 Hz: < 4°
±0.25 % for –FC option
Ext. Sync Mode (not available with -FC option)
Input: Isolated TTL input for external frequency control. Requires 5V at 5 mA for
logic high.
Accuracy: Ext. Sync to phase A with fixed Ext. Sync Frequency input:
16 Hz - 100 Hz: < 2°
100 Hz - 500 Hz: < 3°
> 500 Hz: < 4°
±0.25 % for –FC option
Programmable Output Impedance (available on MX30-3Pi and MX45-3Pi in three phase mode only)
Range: R: 1 – 200 mOhm
L: 15 – 200 uH
N/A N/A N/A
Resolution: R: 1 mOhm
L: 1 uH
N/A N/A N/A
Accuracy: 10 % FS N/A N/A N/A
Note: Output specifications apply below the Current / Voltage rating lines shown in the V/I
rating chart below.