32
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: +49(0)8341 / 9764-0 Fax: +49(0)8341 / 67806
lack of air circulation or due to high ambient temperature, the charging current
is automatically reduced in steps.
Cable lengths and cross-sections
Positive
charging cable
red
Length up to 3 m
Cable cross
section: 6 mm².
Length up to 6 m
Cable cross
section: 10 mm².
Length over
6 m,
Cable cross
section: 16
mm².
Negative
charging cable
blue
Length up to 3 m
Cable cross
section: 6 mm².
Length up to 6 m
Cable cross
section: 10 mm².
Length over
6 m,
Cable cross
section: 16
mm².
Measuring cable B+ red For length of up to 10 m, cable cross-section
0.75 mm².
Cable D+ brown For length of up to 10 m, cable cross-section
0.75 mm².
Function display At least 0.25 mm²
12 V user At least 2.5 mm²
Refrigerator At least 2.5 mm²
Battery II test At least 0.25 mm²
Negative test At least 0.25 mm²
Negative At least 2.5 mm²
Permanent positive for
refrigerator
At least 2.5 mm²
Permanent positive At least 2.5 mm²
Signal from Tremat At least 0.25 mm²
Trigger user relay At least 0.25 mm²
Battery I test At least 0.25 mm²