Maintenance instructions
'1
1
Clean the device and the ventilation slots with a dry, lint-free cloth.
Procedures in the event of faults
The device is maintenance-free. However, if any faults do occur, please
proceed as follows.
Fault Action
The battery is not
being charged.
Check all connections from the power supply to
the
battery. Pay attention to the correct polarity. Remove the
female device plug at the device and plug it back in.
Check the fuses and the mains connection.
The battery volta-
ge has dropped
below 1.5 volt.
Start the motor and let it run for approx. 30 s
econds.
Battery voltage rises above 1.5
volt. The charging
process starts automatically.
Battery II is not
charged during
driving operation.
Check the connection of the cable D+ of the generator
and the fuse.
The maximum
charging current is
not reached.
The device overheats. Ensure better ventilation of the
device.
None of the faults
described here
seems to apply.
But the device still
does not work.
Please contact the manufacturer:
Trautmann GmbH & CO. KG
CALIRA-Apparatebau
Lerchenfeldstr. 9
87600 Kaufbeuren
Telephone: +49(0)8341 976430 Fax: +49(0)8341 976470
Internet:www.calira.de
e-mail: service@calira.de