Chapter 4: Preparing for installation 189
l Grounding cables must not be installed with drip loops.
l Grounding conductors must be securely fastened.
l Braided grounding conductors must not be used.
l Approved bonding techniques must be used for the connection of dissimilar metals.
Ensure that the installation meets the requirements defined in Grounding and lightning protection on page
1.
Grounding and protective earth
The Outdoor Unit (ODU) must be properly grounded to protect against lightning. It is the user’s
responsibility to install the equipment in accordance with national regulations. In the USA follow the
requirements of the National Electrical code NFPA 70-2005 and 780-2004 Installation of Lightning
Protection Systems. In Canada, follow Section 54 of the Canadian Electrical Code. These codes describe
correct installation procedures for grounding the outdoor unit, mast, lead-in wire and discharge unit, size
of grounding conductors and connection requirements for grounding electrodes. Other regulations may
apply in different countries and therefore it is recommended that installation of the outdoor unit be
contracted to a professional installer.
Thermal Safety
The ODU enclosure may be hot to the touch when in operation. The ODU must not be operated in ambient
temperatures exceeding 40°C unless mounted in a Restricted Access Location. For more information, see
ODU ambient temperature limits on page 1.
Warning
Do not install the ODU in a location where the ambient temperature could exceed
40°C unless this is a Restricted Access Location as defined by EN 60950-1.
Alerte
L’unité externe ne doit pas être installée dans un endroit où la température
ambiante est supérieure à 40C à moins que l’accès soit limité au personnel
autorisé.
Preparing for installation
ODU pre-configuration
It is common practice to pre-configure the units during staging before site installation by performing the
following tasks as explained in Configuration Guide.
l Connecting to the unit
l Configuring IP and Ethernet interfaces
l Upgrading the software version and using CNUT
l General configuration

Table of Contents

Other manuals for Cambium Networks PMP 450 AP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cambium Networks PMP 450 AP and is the answer not in the manual?

Cambium Networks PMP 450 AP Specifications

General IconGeneral
BrandCambium Networks
ModelPMP 450 AP
CategoryWireless Access Point
LanguageEnglish

Related product manuals