p. 34 - Manual FA01274-EN - 11/2018 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. Original instructions
RIO safety devices
[RIO ED T1] [Disabled] > [P0] > [P7] > [P8]
RIO-EDGE wireless safety-device to associate to one of the available functions: [P0]= gate stops with exclusion
of any automatic closing; to resume movement, use the control device,[P7] = reopen when closing, [P8] reclose
when opening or [O ]. To program, see the instructions enclosed with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
[RIO ED T2]
RIO-EDGE wireless safety device - See function called [RIO ED T1]
[RIO PH T1] [Disabled] > [P1] > [P2] > [P3] > [P4] > [P13]
RIO-CELL wireless device associated to one of the available functions: [P1] = reopen when closing; [P2]
= reclose when opening; [P3] = partial stop; [P4] = obstruction wait; [P13] = reopen when closing with
immediate closing once the obstruction is removed, even when the gate is stopped. [OFF] = o .
This function only appears if the RIOCN8WS card is plugged into the control board.
The [P3] function is enabled on if if the [Automatic close] automatic close is turned on.
[RIO PH T2]
RIO-CELL wireless device - See the [RIO PH T1] function
[CY input]
Input NC – See function [CX Input]
[CZ input]
Input NC – See function [CX Input]
[Input CK]
Input NC – See function [CX Input]
[Safety devices test] [O ] > [On]
After every opening or closing command, the board will check whether the photocells are working properly.
The safety test is always active for wireless devices.
[Obst. with motor stopped] [O ] > [On]
When the gate is closed, open or, after a total stop, the operator stays idle if the safety devices, namely, photocells
or sensitive safety-edges detect an obstruction.
Command inputs
[Command 2-7] function [Step-by-step] > [Sequential]
From the safety device connected to 2-7, it performs the (open, stop-close-stop) sequential (open-close-invert)
step-by-step command,

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME BKV20ALS and is the answer not in the manual?

CAME BKV20ALS Specifications

General IconGeneral
BrandCAME
ModelBKV20ALS
CategoryGate Opener
LanguageEnglish

Related product manuals