~1°
p. 21 - Manual FA00571-EN v. 1 - 08/2017- © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice.
ESTABLISHING THE LIMIT-SWITCH POINTS
Close the inspection hatch and power up the system. Move the boom the check that it is parallel to the road surface when closed and
at about 89° when open.
⚠
The barrier's opening and closing maneuvers must be performed with the inspection hatch closed.
To correct the boom's vertical position:
- lower the boom;
- open the inspection hatch;
- turn the jointed arm clockwise or counter-clockwise to increase or decrease the boom travel .
Fasten the boom using the counter nuts , above and below .
To correct the horizontal position:
- raise the boom;
- turn the mechanical limit-switch stop clockwise to increase the boom travel or counter clockwise to decrease it .
Fasten the stop using the screw .
Mechanical stop
UNI 5739 6X20 bolt