secured. • The operator must not be used with guided parts that have openings
exceeding 50 mm in diameter, or that have protruding edges/parts someone could
grab or stand on. • Make sure that nobody can become trapped between the
guided and fixed parts, when the guided part is set in motion. • All fixed controls
must be clearly visible after installation, in a position that allows the guided part
to be directly visible, but far away from moving parts. All fixed controls must be
installed at least 1.5 m above the floor. • Where operated with a hold-to-run
control, install a STOP button to disconnect the main power supply to the operator,
to block movement of the guided part. • Install the manual release device below
1.8 m. If the manual release device is removable, store it somewhere near the
operator. • If not already present, apply a permanent tag that describes how to
use the manual release mechanism close to it. • Make sure that the operator
has been properly adjusted and that the safety and protection devices and the
manual release are working properly. Check that the operator inverts the motion
when the guided part comes into contact with an object 50 mm tall positioned
on the pavement. • Following installation, ensure that the guided part does not
extend onto any public footpaths or roads. • Before handing over to the final user,
check that the system complies with the harmonised standards and the essential
requirements of the Machinery Directive (2006/42/EC). • Permanently affix the
risk of entrapment labels somewhere visible or near any of the fixed controls. •
Any residual risks must be indicated clearly with proper signage affixed in visible
areas, and explained to end users. • Put the machine’s ID plate in a visible place
when the installation is complete. • If the power supply cable is damaged, it
must be immediately replaced by the manufacturer or by an authorised technical
assistance centre, or in any case, by qualified staff, to prevent any risk. • Keep
this manual inside the technical folder along with the manuals of all the other
devices used for your automation system. • Make sure to hand over to the end
user all the operating manuals of the products that make up the final machinery. •
The product, in its original packaging supplied by the manufacturer must only be
transported in a closed environment (railway carriage, containers, closed vehicles).
• If the product malfunctions, stop using it and contact customer services at
serviceinternational@came.com or via the telephone number on the website.
The manufacture date is provided in the production batch printed on the product label. If necessary,
contact us at https://www.came.com/global/en/contact-us.
The general conditions of sale are given in the official CAME price lists.
p. 4 -