9 - Manual FA01796-IT - 04/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device Output Power supply (V) Maximum power (W)
Accessories 10 - 11 26 AC 20
Additional light 10 - E3 26 AC 10
Flashing beacon 10 - E 26 AC 10
Operator status warning light 10 - 5 26 AC 3
The outputs deliver 24 V DC when the batteries start operating, if they are installed.
Connecting gearmotors without R interface (control board 119RIR267)
Connection with slowdown microswitch Connection with limit-switch/slowdown microswitch
FC1 FA1 F FC2 FA2 F
M
N
R
RA
RC
N
M
RC
RA
M1 N1 ENC1 EB1+VB
R1
M2 N2 ENC2 EB2+VB
R2
M1 M2
R
FC1 FA1 F FC2 FA2 F
M
N
F
FA
RC
N
M
RC
FA
F
M1 N1 ENC1 EB1+VB
R1
M2 N2 ENC2 EB2+VB
R2
M1 M2
R
R
Set the function [F72 - Limit-switch function] taking into account the chosen connection.