Adjusts automatic closing time from a minimum of 1 sec to a maximum of 120 sec.
= Adjusts automatic opening time from a minimum of 1 sec to a maximum of 14 sec
Automatic closure activated; (1 OFF-deactivated)
“Open-stop-close-stop” function with button (2-7) and transmitter (AF board inserted) activated;
-“Open-close” function with button (2-7) and transmitter (AF card inserted) activated;
- “Only opening” function with transmitter (AF card inserted) activated; (3 OFF-deactivated)
-“Maintained Action” function (excludes the function of the transmitter) activated; (4 OFF-deactivated)
“Pre-fl ashing during opening/closing activated; (5 OFF-deactivated)
-Obstacle detection activated; (6 OFF-deactivated)
“Re-closing while opening” function (connect the safety device on clamps 2-C1) activated;
“Re-closing while opening” function (connect the safety device on clamps 2-CX) activated;
“Partial stop” function (connect the safety device on clamps 2-CX) activated;
(if the devices on the 2-CX clamps are not used, set Dip 8 to ON)
Total stop” function (connect the button onto clamps 1-2) activated; (10 ON - deactivated)
-“Slave” function deactivated (to activate in the event of coupled connection)
“Partial opening” function (automatic closing is fi xed at 8 seconds) activated;
“Partial opening” function (automatic closing is adjusted with the trimmer, if on/inserted) activated;
“Safety test” function to check the effi ciency of the photoelectric cells (see page 14) activated;
-“Master” function deactivated (to activate in the event of coupled connection);
- Not used, keep the dip switch in the “OFF” position
“Courtesy light function activated”; (16 OFF-deactivated)
“Lamp cycle” activated; (17 OFF-deactivated)
- Activates brake during closure- (CBX, CBXT).