8
ENGLISH
+T.C.A.
-
+AP.PARZ.
-
Trimmer T.C.A.
=
Adjusts automatic closing time from a minimum of 1 sec to a maximum of 120 sec.
Part. Op. Trimmer.
Part. Op. Trimmer.
= Adjusts automatic opening time from a minimum of 1 sec to a maximum of 14 sec
5.8
Adjustment Trimmer
1 ON
Automatic closure activated; (1 OFF-deactivated)
2 ON
“Open-stop-close-stop” function with button (2-7) and transmitter (AF board inserted) activated;
2 OFF
-“Open-close” function with button (2-7) and transmitter (AF card inserted) activated;
3 ON
- “Only opening” function with transmitter (AF card inserted) activated; (3 OFF-deactivated)
4 ON
-“Maintained Action” function (excludes the function of the transmitter) activated; (4 OFF-deactivated)
5 ON
“Pre-fl ashing during opening/closing activated; (5 OFF-deactivated)
6 ON
-Obstacle detection activated; (6 OFF-deactivated)
7 OFF
“Re-closing while opening” function (connect the safety device on clamps 2-C1) activated;
(7 ON-deactivated)
8 OFF/ 9 OFF
“Re-closing while opening” function (connect the safety device on clamps 2-CX) activated;
8 OFF/ 9 ON
“Partial stop” function (connect the safety device on clamps 2-CX) activated;
(if the devices on the 2-CX clamps are not used, set Dip 8 to ON)
10 OFF
Total stop” function (connect the button onto clamps 1-2) activated; (10 ON - deactivated)
11 OFF
-“Slave” function deactivated (to activate in the event of coupled connection)
12 ON
“Partial opening” function (automatic closing is fi xed at 8 seconds) activated;
12 OFF
“Partial opening” function (automatic closing is adjusted with the trimmer, if on/inserted) activated;
13 ON
“Safety test” function to check the effi ciency of the photoelectric cells (see page 14) activated;
(13 OFF-deactivated)
14 OFF
-“Master” function deactivated (to activate in the event of coupled connection);
15
- Not used, keep the dip switch in the “OFF” position
16 ON
“Courtesy light function activated”; (16 OFF-deactivated)
17 ON
“Lamp cycle” activated; (17 OFF-deactivated)
18
ON
- Activates brake during closure- (CBX, CBXT).
19
- Not connected
20
- Not connected
1 2 3 4
NO
5 6 7 8
9 01
1
11
2
12
3
13
4
14
NO
5
15
6
16
7
17
8
18
9
19
0
1
20
+T.C.A.-
+AP.PARZ.-
2 3 4
O N
5 6 7 8
9 1 0
 

  
 






AF
R
S
T
U
V
W
RED
WHITE
WHITE
BLUE
BLUE
400V
400V
230V
230V
COMM.
COMM.






CONTROL BOARD
WARNING!
+T.C.A.-
+T.C.A.-
+T.C.A.-
+T.C.A.-
+AP.PARZ.-
+AP.PARZ.-
+AP.PARZ.-
F.CH/CH1
F.AP/CH2
1 2 3 4
O N
5 6 7 8
9 1 0
1

2
2

3

4

O N
5

6
6

7

8

9

1 0







AF
R
S
T
U
V
W
RED
WHITE
WHITE
BLUE
BLUE
400V
400V
230V
230V
COMM.
COMM.






8A
LINE FUSE
LINE FUSE
ZT6
CONTROL BOARD
2A
ACCESSORIES
WARNING!

Other manuals for CAME ZT6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME ZT6 and is the answer not in the manual?

CAME ZT6 Specifications

General IconGeneral
BrandCAME
ModelZT6
CategoryControl Panel
LanguageEnglish

Related product manuals