Remove the three socket-head capscrews from the other end of the me-
ter body.
Remove the second bearing support, rotating it if necessary.
Examine the carbide bearing and rotor shaft. If either part is worn or
damaged, replace all internals with a repair kit (page 28).
Reassembling the Round-Body Meter
An arrow indicating direction of ow is cast or engraved on the meter
body, rotor, and bearing supports. When the meter is assembled, all
arrows must point in the direction that product will ow through the
meter.
During calibration, punch marks are placed on the meter body and the
bearing supports to mark the positions of the bearing supports. During
assembly, the punch marks must be realigned for maximum accuracy.
Never use force when assembling meter components. The tungsten
carbide rotor shaft is brittle and can break under excessive force.
4.
5.
6.