7.4.3 HST Oil
Inspection/Refilling
1. Park the machine in a horizontal place.
2.
Check the amount of oil. When it is insufficient, supply oil (Page 14)
Oil to be used : page 28
Amount of HST oil: 4.1 lit.
Replacement
1. Prepare a suitable container to collect drained oil.
2. Remove the drain plug and drain oil.
Properly dispose of drained oil.
3. Replace the drain plug.
4. Open the refueling cap and put in a proper amount
of designated oil.
NOTE
– 32
MAINTENANCE
Replacement
1. Prepare an appropriate container to collect oil.
2. Remove drain plug and drain oil into container.
Hot oil can cause burns.
CAUTION
Properly dispose of drained oil.
3. Replace drain plug.
4. Open the oil plug and pour the designated oil.
NOTE
Drain plug
Refueling cap
HST oil tank
Oil checking port
Drain plug