One or all cooking zone cut-off:
The safety system functioned.
You forgot to cut-off the cooking zone for a long time.
One or more sensitive keys are covered.
The pan is empty and its bottom overheated.
The hob also has an automatic reduction of power level and breaking Automatic
overheating.
The control panel displays [ L ]:
Refer to the chapter control panel locking page.
The control panel displays [ Er03 ]:
An object or liquid covers the control keys. The symbol disappears as soon as the key is
released or cleaned.
The control panel displays [ E2 ] or [ EH ]:
The hob is overheated, let it cool and then turn it on again.
The control panel displays [ E3 ]:
The pan is not adapted, change the pan.
The control panel displays [ E5 ]:
Defective network. Control the voltage of the electrical network.
The control panel displays [ E6 ]:
Defective network. Control the frequency of the electrical network.
The control panel displays [ E8 ]:
The air inlet of the ventilator is obstructed, release it.
The control panel displays [ U400 ]:
The hob is not connected to the network. Check the connection and reconnect the hob.
If one of the symbols above persists, contact Caple Service.