8
USES
CE920WH must be installed with external motors manufactured by the same
producer. The motor does not come included and must be ordered separately.
PANELS OPENING
It is possible to open the panel, which covers the grease filters, by slightly pulling on
a side of the panel itself, as shown in Fig. 1.
For proper working, it is recommended to install the appliance at a distance of
2000 - 2100 mm from the floor.
Before starting the appliance installation, please check that all components are not
damaged, in such a case contact your retailer and do not carry out installation.
Furthermore, please read carefully all of the following installation instructions.
- Use an exhausting pipe whose maximum length does not exceed 5 meters.
- Limit the no. of elbows in the piping, since each elbow reduces the air capacity of
1 linear meter. (Eg.: if you use no. 2 x 90 ° elbows, the length of piping must not
exceed 3 meters).
- Avoid abrupt direction changes.
- Use a 150 mm constant diameter pipe for the whole length.
- Use piping approved by standards in force.