SETUP AND CALIBRATION, Cont.
bAUd= (Serial Port Baud Rate)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, use the numeric keys to enter a new baud rate for the
serial ports, then press the
ENTER
key to save it. Allowable values are:
12 = 1200 Baud 24 = 2400 Baud 48 = 4800 Baud
96 = 9600 Baud 19 = 19.2k Baud 38 = 38.4k Baud
76 = 76.8k Baud
Prty= (Serial Port Parity)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are: 0, 1, or 2.
0 = NONE (No Parity) 1 = Odd Parity 2 = Even Parity
bitS= (Serial Port Data Bits)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are: 7 or 8.
StoP= (Serial Port Stop Bits)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are: 1 or 2.
Cont1= (Continuous Output Serial Port 1)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys,
0/NO
or
1/YES
, enter the new
setting, then press the
ENTER
key to save it.
Cont1= 1 (Yes) Cont1= 0 (No)
Continuous Output No Continuous Output
If you selected Cont1= 1 (Yes Continuous Output), an additional prompt, "tyPE=" will be displayed.
If you selected Cont1= 0 (No Continuous Output) proceed to the Weight On Demand section.
tyPE= (Continuous Output Format)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are: 0, 1, 2 or 3.
0 = SMA 1 = SB-400 2 = SB-200 3 = Rice Lake IQ355
If SMA is selected, the data will be transmitted in the following format:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
lf = Line Feed
s = Flags Z= center of Zero, O = Overcap, E = zeroError,
e = weight not currently being displayed
r = Range 1, 2, 3, ...
n = Mode G = Gross, T = Tare, N = Net
m = Motion M = Motion, " "(
blank
) = no motion
f = Custom Custom flag
xxxxxx.xxx = Weight Six digits with decimal point
uuu = Units ton, lb , l/o, oz , t , kg , g
cr = Carrriage Return (hex 0D)

Other manuals for Cardinal 200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 200 Series and is the answer not in the manual?

Cardinal 200 Series Specifications

General IconGeneral
BrandCardinal
Model200 Series
CategoryAccessories
LanguageEnglish

Related product manuals