SETUP AND CALIBRATION, Cont.
n ACC= (Net Weight Accumulator Print Location)
Press the
ENTER
key to show the current setting for the location of the Net weight accumulator
printing. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise,
use the numeric keys to enter the new location then press
ENTER
to save it.
CoUnt= (Count "number of pieces on the scale" Print Location) -
Model 210 Only
Press the
ENTER
key to show the current setting for the location of the Count (number of pieces
on the scale) printing. If the setting displayed is acceptable, press the
ENTER
key again to save it.
Otherwise, use the numeric keys to enter the new location then press
ENTER
to save it.
EACH= (Piece Weight Print Location) -
Model 210 Only
Press the
ENTER
key to show the current setting for the location of the Piece weight printing. If
the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, use the
numeric keys to enter the new location then press
ENTER
to save it.
CrLF= (Carriage Return Line Feed) -
Data Format Termination
Data transmitted from the serial I/O port can be terminated with a single carriage return and either
no line feed or a single line feed command. Press the
ENTER
key to view the current setting. A
"YES" on the display means the data will be terminated with a carriage return AND a line feed
while a "no" on the display means the data will be terminated with a single carriage return only.
If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the
numeric keys,
0/NO
or
1/YES
, enter the new setting, then press the
ENTER
key to save it.
EoP= (End-Of-Print Line Feeds)
At the end of a data transmission to a printer, the indicator can transmit a pre-selected number of
line feed commands to space the paper in the printer to the desired position for withdrawal or for
the next print.
Press the
ENTER
key to view the current setting. If the displayed value is acceptable, press the
ENTER
key to save it. Otherwise, use the numeric keys to enter the new the number of End-Of-
Print linefeeds, then press the
ENTER
key to save the new setting. Allowable values are: 0
through 99.
F SPAn (FSPAn?) - Fine Span Adjustment
With the F SPAn? prompt displayed after pressing the ENTER key at the last Print prompt:
With F SPAn? displayed, press the
ENTER
key. The display will change to show the current
setting “no”. To skip the Fine Span Adjustment and return to the SEtUP menu, press the
ENTER
key again. To perform the Fine Span Adjustment, place a calibrated test weight on the
scale and press the numeric key
1/YES
then the
ENTER
key.
After pressing the
ENTER
key, the display will change to show the amount of the test weight
and the annunciators will alternately flash off and on i.e. (all ON, weighing unit off, then all OFF,
weighing unit ON). Press the
1/YES
to increase the span
OR
press the
0/NO
key to decrease
the span. Press the ASTERISK key to return to the previous prompt or press the
ENTER
key
to exit F SPAn and return to the SetUP menu.
With the F SPAn prompt displayed after pressing the Calibration switch:
With F SPAn displayed, place a calibrated test weight on the scale and press the
ENTER
key.
After pressing the
ENTER
key, the display will change to show the amount of the test weight
and the annunciators will alternately flash off and on (all ON, weighing unit off, then all OFF,
weighing unit ON). Press the
1/YES
to increase the span
OR
press the
0/NO
key to decrease
the span. Press the
ASTERISK
key to return to the previous prompt or press the
ENTER
key to
exit F SPAn and return to the SEtUP menu.