8555-M313-O1 Rev H 204 Installation & Technical
18
SETUP AND CALIBRATION, CONT.
SLP= (Sleep Mode)
The display will now show SLP=. The Sleep Mode feature also conserves battery power when
the indicator remains unused for a selected period of time. With the feature enabled, the load
cell excitation will be reduced and the display will show SLEEP. The Sleep feature requires
that the indicator remain at the center of zero to activate, unlike the Automatic Shutoff feature
which only requires no motion. Weight placed on the scale will activate the indicator and
return it to the weight mode.
Press the ASTERISK key to show the current setting. To enable, use the UNITS key to select
the number (1 to 9) of minutes (time approximate) of inactivity at zero before the indicator will
enter the Sleep mode. Press the PRINT key to save the setting. Enter a 0 to disable the
Sleep mode. NOTE: This setting may be revised during Setup Review.
bAUd= (Baud Rate Selection)
The display will now show bAUd=. Press the ASTERISK key to show the current setting. If
acceptable, press the PRINT key to save it. Otherwise use the UNITS key to select the
desired baud rate and press the PRINT key to save the setting. NOTE: The FACTORY
setting is 3 (9600 baud) and may be revised during Setup Review. Allowable values are:
0 = 1200 1 = 2400 2 = 4800 3 = 9600 4 = 19,200 5 = 38,400
Prty= (Serial Port Parity)
The display will now show PrtY=. Press the ASTERISK key to view the current setting. If
acceptable, press the PRINT key to save it. Otherwise use the UNITS key to select a new
value for the parity and press the PRINT key to save the setting. NOTE: This setting may be
revised during Setup Review. Allowable values are:
0 = NONE (No Parity) 1 = Odd Parity 2 = Even Parity
Prt= (Print Ticket Format)
The display will now show Prt=. Press the ASTERISK key to view the current setting. If
acceptable, press the PRINT key to save it. Otherwise use the UNITS key to change the
selected print ticket format. NOTE: This setting may be revised during Setup Review.
Allowable values are:
0 = Default Format 1 = nControl Format 1 2 = nControl Format 2
COnt= (Continuous Output)
The display will now show COnt=. Press the ASTERISK key to view the current setting. If a 1
(1=YES) is displayed, the feature has been enabled and the 204 will send a continuous output
of weight data to the serial I/0 connector. If a 0 (0=NO) is displayed the data will only be
transmitted when the PRINT key is pressed or on receipt of an ENQ command from a
computer. Press the UNITS key to change between 1 (YES) and 0 (NO). Once the proper
setting is displayed, press the PRINT key to save the setting. NOTE: This setting may be
revised during Setup Review.
EOP= (End-Of-Print Line Feeds)
The display will now show EoP=. At the end of a data transmission to a printer, the 204 can
send a number of line feed commands to space the paper in the printer to the desired position
for withdrawal or for the next print. Press the ASTERISK key to view the current setting. If the
setting shown is acceptable, press the PRINT key to save it. Otherwise, use the UNITS key to
select the desired number of line feeds (0 to 99). With the desired number displayed, press
the PRINT key to save the setting. NOTE: This setting may be revised during Setup Review.
Setup and Calibration Completed
The setup and calibration process has been completed. The indicator will reset and then
display weight. Remove power from the indicator and re-assemble for use..