15
SETUP AND CALIBRATION, Cont.
Battery Type
With the display showing
niCAd=
press the ASTERISK key to show current setting, then press
UNITS
to select 1 if NiCad or NiMH batteries are going to be used
or
0, if using Alkaline
batteries. Press the PRINT key to save the setting. Note: This setting may be revised without
having to enter the calibration mode.
CAUTION: Selecting 1, enables battery charging. DO
NOT select 1, when using
Alkaline batteries.
Power Up Zero
With the display showing
PUO=
press the
ASTERISK
key to show current setting, then press
UNITS
to select 1 (1=YES, enable) or 0 (0=NO, disable). Press the
PRINT
key to save the
setting.
Note:
This setting may be revised without having to enter the calibration mode.
• If 1=YES is selected, the weight display will be reset to zero automatically on power up.
•
If 0=NO is selected, the weight display will not be reset to zero.
Automatic Shutoff
The display will now show
ASH=
. This Automatic Shutoff feature will automatically turn the 204
off after a predetermined period of inactivity to prolong battery life. To turn the indicator back
on you must press the
ON / OFF
key.
Press the
ASTERISK
key to show the current setting. Use the
UNITS
key to select the
number (1 through 9) of minutes (
time approximate
) of inactivity before turning the 204 off. A 0
disables the Automatic Shutoff feature. Press the
PRINT
key to save the setting.
Note:
This
setting may be revised without having to enter the calibration mode.
Sleep Mode
The display will now show SLP=. The Sleep Mode feature also conserves battery power when
the indicator remains unused for a selected period of time. With the feature enabled, the load
cell excitation will be reduced and the display will show
SLEEP
. The Sleep feature requires that
the indicator remain at the center of zero to activate, unlike the Automatic Shutoff feature
which only requires no motion. Weight placed on the scale will activate the indicator and
return it to the weight mode.
Note:
This setting may be revised without having to enter the
calibration mode.
Press the
ASTERISK
key to show the current setting. To enable, use the
UNITS
key to select
the number (1 to 9) of minutes (
time approximate
) of inactivity at zero before the indicator will
enter the Sleep mode. Press the
PRINT
key to save the setting. Enter a 0 to disable the
Sleep mode.
Note:
This setting may be revised without having to enter the calibration mode.
Baud Rate Selection
The display will now show
bAUd
. Press the
ASTERISK
key to show the current setting. If
acceptable, press the
PRINT
key to save it. Otherwise use the
UNITS
key to select the
desired baud rate and press the
PRINT
key to save the setting.
Note:
The FACTORY setting
is 3 (9600 baud) and may be revised without having to enter the calibration mode. The
following baud rates are available:
0 = 1200 1 = 2400 2 = 4800 3 = 9600 4 = 19,200 5 = 38,400