8200-M129-O1 Rev D 205 Installation & Technical 25
SETUP AND CALIBRATION, CONT.
LFt= (Legal For Trade)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER key again to save it. Otherwise, use the /UP ARROW key to toggle
to a new setting and then press the TARE/ENTER key to save it.
LFt=1 LFt=0
Interval Settings (Int=) allowed
are: 1, 2, 5, 10 , 20, 50
Interval Setting (Int=) is
selectable from 1 to 99.
NOTE: When both
LFt=1
and
USA=1
, the followings results occur:
Scale must have between 100 and 10,000 divisions
Tra = .5 or 0 to 3
Inhibit serial data during input
Trl = no
Cap + 4% to OC
Display will show “Accumd” momentarily whenever the Gross or Net
accumulator is updated
NOTE: When
LFt=1
and
USA=0
, the followings results occur:
Uns = 1
Trl = yes
Cap + 9 grads to OC
PT printed with tare
Lamp test on power up
Display will show “Accumd” momentarily whenever the Gross or Net
accumulator is updated
Unit1= (Weighing Unit 1)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER key again to save it. Otherwise, use the /UP ARROW key to toggle
to a new setting and then press the TARE/ENTER key to save it. Allowable values are:
0 = none 4 = oz (ounces)
1= tn (tons) 5 = kg (kilograms)
2= g (grams) 6 = tonnes (metric tons)
3 = lb (pounds) 7 = lb/oz (pounds/ounces)
int= (Interval Setting)
Press the TARE/ENTER key to show the current value.
If LFt = 1 (Legal For Trade = YES), use the /UP ARROW key to toggle to a new
setting and then press the TARE/ENTER key to save it. Allowable values are: 1, 2, 5, 10,
20 or 50.
If LFt=0 (Legal For Trade = NO), use the /UP ARROW and UNITS/LEFT ARROW keys
to enter a new setting and then press the TARE/ENTER key to save it. Allowable values
are: 1 through 99.
In either case, if the setting displayed is acceptable, press the TARE/ENTER key again it.