8200-M129-O1 Rev D 205 Installation & Technical 49
SETUP AND CALIBRATION, CONT.
Print (Print?) - Print Tab Settings
With Print (Print?) displayed, press the TARE/ENTER key. The display will change to
show the current setting no. To skip configuring the Print Tab Settings and proceed to the
FSPAn? menu, press the TARE/ENTER key again. To configure Print Tab Settings, press the
/UP ARROW key to select YES and then the TARE/ENTER key. After pressing the
TARE/ENTER key the display will change to Port=.
The general format for the input is A = YY.XX where A is the
character identifying the data printed, YY is the number of lines
down and XX is the number of spaces to the right.
NOTE: Enter 00 in either the YY or XX location to
disable the data from printing.
Port= (Select Port for Printer)
Press the TARE/ENTER key to show the current value. If the
setting displayed is acceptable, press the TARE/ENTER` key
again to save it. Otherwise, use the /UP ARROW key to toggle to a new setting and then
press the TARE/ENTER key to save it. Allowable values are: 0, 1, 2 or 3 (for port 0 through
port 3) and 4 for the optional 2xx-RS232 card (if installed).
GroSS= (Gross Weight Print Location)
Press the TARE/ENTER key to show the current setting for the location of Gross weight
printing. If the setting displayed is acceptable, press the TARE/ENTER key again to save it.
Otherwise, use the /UP ARROW and UNITS/LEFT ARROW keys to enter a new location
and then press TARE/ENTER to save it.
tArE= (Tare Weight Print Location)
Press the TARE/ENTER key to show the current setting for the location of Tare weight
printing. If the setting displayed is acceptable, press the TARE/ENTER key again to save it.
Otherwise, use the /UP ARROW and UNITS/LEFT ARROW keys to enter a new location
and then press TARE/ENTER to save it.
nEt= (Net Weight Print Location)
Press the TARE/ENTER key to show the current setting for the location of Net weight printing.
If the setting displayed is acceptable, press the TARE/ENTER key again to save it. Otherwise,
use the /UP ARROW and UNITS/LEFT ARROW keys to enter a new location and then
press
TARE/ENTER to save it.
G ACC= (Gross Weight Accumulator Print Location)
Press the TARE/ENTER key to show the current setting for the location of Gross weight
accumulator printing. If the setting displayed is acceptable, press the TARE/ENTER key again
to save it. Otherwise, use the /UP ARROW and UNITS/LEFT ARROW keys to enter a new
location and then press TARE/ENTER to save it.
n ACC= (Net Weight Accumulator Print Location)
Press the TARE/ENTER key to show the current setting for the location of Net weight
accumulator printing. If the setting displayed is acceptable, press the TARE/ENTER key again
to save it. Otherwise, use the /UP ARROW and UNITS/LEFT ARROW keys to enter a new
location and then press TARE/ENTER to save it.