8200-M129-O1 Rev D 205 Installation & Technical 34
SETUP AND CALIBRATION, CONT.
Dual-Point with Zero (First Zero) Calibration
IMPORTANT! The functions of numeric keys are replaced by using the UNITS/LEFT
ARROW and the /UP ARROW keys. The cursor location is identified by the
blinking character and can be advanced to the left to the next position by pressing
the UNITS/LEFT ARROW key. Pressing the /UP ARROW key will change the
blinking character to the next value.
CAL1= – First Calibration Weight
The display will show CAL1=0. This is the first of two calibration weights. This weight
could be ZERO (NO LOAD) or the TEST WEIGHTS / TEST LOAD.
If the first calibration weight is to be ZERO (NO LOAD), press the TARE/ENTER key.
If the first calibration weight is to be the TEST WEIGHTS / TEST LOAD, use the
UNITS/LEFT ARROW and the /UP ARROW keys to input the value of the calibrated
test weights. NOTE! When entering values for CAL1=, the digits start displaying on
the right side of the display and proceed to the left. When large values are used (more
than 3 digits), the CAL1= prompt will automatically scroll off the left side of the display
to show the additional digits on the right as they are entered.
Place the weights on the scale platform, then press the TARE/ENTER key.
Starting at the left and advancing right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the display
will show: CAL2=.
CAL2= - Second Calibration Weight
The display will show CAL2=0. This is the second of two calibration weights. This
weight could be ZERO (NO LOAD) or the TEST WEIGHTS / TEST LOAD.
If the second calibration weight is to be ZERO (NO LOAD), press the TARE/ENTER key.
If the second calibration weight is to be the TEST WEIGHTS / TEST LOAD, use the
UNITS/LEFT ARROW and the /UP ARROW keys to input the value of the calibrated
test weights. NOTE! When entering values for CAL2=, the digits start displaying on
the right side of the display and proceed to the left. When large values are used (more
than 3 digits), the CAL2= prompt will automatically scroll off the left side of the display
to show the additional digits on the right as they are entered.
Place the weights on the scale platform, then press the TARE/ENTER key.
Starting at the left and advancing right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the display
will show: Sio?.