8200-M129-O1 Rev D 205 Installation & Technical 44
SETUP AND CALIBRATION, CONT.
StoP1= (Serial Port 1 Stop Bits)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it. Allowable values are:
1 = 1 Stop Bit 2 = 2 Stop Bits
Cont1= (Continuous Output Serial Port 1)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it.
Cont1= YES Cont1= no
Continuous Output No Continuous Output
If Cont1= YES (Continuous Output) is selected, an additional prompt, tYPE1=
will be displayed.
If Cont1= no (No Continuous Output) is selected, proceed to the Weight On
Demand section.
tyPE1= (Continuous 1 Output Format)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER key again to save it. Otherwise, using the numeric keys enter the
new setting, then press the TARE/ENTER key to save it. Allowable values are:
0 = SMA 1 = SB-400 2 = SB-200
3 = Rice Lake IQ355 4 = AnDFV 5 = WI110
6 = Number Only 7 = Toledo Long/Short 8 = SB500 with Traffic Light
9 = Ranger 5000 Format A
If tYPE1=7 (Toledo Long/Short) is selected, an additional prompt, tShort will
be displayed.
tShort= (Toledo Short)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it.
tShort= YES tShort= no
Toledo Short Output Format Toledo Long Output Format
Sio 2? (Setup Serial Port 2)
Press the TARE/ENTER key. The display will change to show the current setting no. To skip
configuring the Sio Port 2 (serial input/output) and proceed to the Sio 3? menu, press
the TARE/ENTER key again. To configure the Sio 2, press the /UP ARROW key to select
YES and then press the TARE/ENTER key.