EasyManua.ls Logo

Cardinal 748 - Page 12

Cardinal 748
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Hex Format to Transmit - 2H 34H 33H 34H 3H
Equivalent Computer or Terminal Keys to press - Ctrl B 4 3 4 Ctrl C
KeyCommand - 5
Equivalent Keyboard Key - TARE
Function - Enter a Tare weight value
Serial Command Format - STX5xxxxxxCKsumETX
(xxxxxx = the tare weight value)
Hex Format to Transmit - 2H 35H xH xH xH xH xH xH
1
zzH
2
3H
Equivalent Computer or Terminal Keys to press - Ctrl B 5 xxxxxx zz
3
Ctrl C
KeyCommand - 6
Equivalent Keyboard Key - BAR
Function - Enter the Bar Graph Starting (60) and Stop (61)
weight values
Serial Command Format - STX60xxxxxxCKsumETX
(xxxxxx = the Bar Graph Starting Weight)
STX61yyyyyyCKsumETX
(yyyyyy = the Bar Graph Stop Weight)
Hex Format to Transmit - 2H 36H 30H xH xH xH xH xH xH
1
zzH
2
3H
(Start weight command)
2H 36H 31H yH yH yH yH yH yH
2
zzH
2
3H
(Stop weight command)
Equivalent Computer or Terminal Keys to press - Ctrl B 6 0 xxxxxx zz
3
Ctrl C
(Start Weight command)
Ctrl B 6 1 yyyyyy zz
3
Ctrl C
(Stop Weight command)
NOTE: This command will not change from the PWC to Bar Graph mode in the display. It must be
manually selected.
KeyCommand - 7
Equivalent Keyboard Key - PRESET
Function - Enter the Preset or Trim weight value for one or all
eight of the preset weight comparators
Serial Command Format - STX7nxxxxxxCKsumETX
n = the preset or trim weight comparator number
(see below).
(xxxxxx = the weight value for the corresponding
preset number)
Hex Format to Transmit - 2H 37H nH xH xH xH xH xH xH
1
zzH
2
3H
Equivalent Computer or Terminal Keys to press - Ctrl B 7 n xxxxxx zz
3
Ctrl C
Preset and Trim values for “n.
Note values for “n” are in HEX.
1 set preset 1 7 set preset 4 D set preset 7
2 set trim 1 8 set trim 4 E set trim 7
3 set preset 2 9 set preset 5 F set preset 8
4 set trim 2 A set trim 5 G set trim 8
5 set preset 3 B set preset 6
6 set trim 3 C set trim 6
NOTE: This command will not change from the Bar Graph to PWC mode in the display. It must be
manually selected.
KeyCommand - 8
Equivalent Keyboard Key - none
Function - Initiates an inquiry (ENQ) of the bi-directional I/O
port. This command will cause the displayed
weight to transmit out the serial I/O port.