Jason LeeAug 20, 2025
What to do if the CareFusion Alaris shows 'Low Battery'?
- JJustin RobinsonAug 20, 2025
If the CareFusion Medical Equipment displays a 'Low Battery' message, connect it to a power source. This should silence the alarm.
What to do if the CareFusion Alaris shows 'Low Battery'?
If the CareFusion Medical Equipment displays a 'Low Battery' message, connect it to a power source. This should silence the alarm.
What to do if CareFusion Alaris says 'Battery Discharged'?
If the CareFusion Medical Equipment indicates 'Battery Discharged', connect the AC power cord to a power source to silence the alarm. If you want to continue operation of paused modules, press the RESTART key on the affected module.
What to do if CareFusion Alaris Medical Equipment shows 'Very Low Battery
If the CareFusion Medical Equipment displays 'Very Low Battery
What to do if CareFusion Alaris displays 'Channel Disconnected'?
If the CareFusion Medical Equipment displays 'Channel Disconnected', press the CONFIRM soft key to silence the alarm and clear the message from the screen. If needed, reattach the module, making sure it "clicks" securely into place at the Module Release Latch. If the alarm persists, replace the module.
What to do if CareFusion Alaris displays 'Replace Battery'?
If the CareFusion Medical Equipment displays 'Replace Battery', you can press the CONFIRM soft key to continue normal operation with reduced battery capacity. Replace the PC Unit.
What to do if CareFusion Alaris shows 'Battery Run Time = X.X hours'?
If the CareFusion Medical Equipment displays 'Battery Run Time = X.X hours', connect the AC power cord to a power source as soon as possible.
What to do if the CareFusion Medical Equipment shows 'Channel Error'?
If the CareFusion Medical Equipment displays a 'Channel Error', press the CONFIRM soft key to silence the alarm and continue operation of unaffected modules. Replace the module.
What to do if CareFusion Alaris shows 'Power Supply Error'?
If the CareFusion Medical Equipment displays 'Power Supply Error', immediately disconnect the AC power. To continue operation under battery power, press the SILENCE key. Replace the PC Unit.
What to do if CareFusion Alaris displays 'Audio System Error'?
If the CareFusion Medical Equipment displays 'Audio System Error', visually check the alarm status to determine if an operational alarm also needs attention (indicated by a lit red Alarm Status Indicator). Replace the PC Unit.
What to do if CareFusion Alaris displays 'System Error'?
If the CareFusion Medical Equipment displays 'System Error', press the SILENCE key to continue temporary operation. Replace the PC Unit.
| Power Supply | 100-240 VAC, 50/60 Hz |
|---|---|
| Device Type | Infusion Pump System |
| Model | Alaris |
| Manufacturer | CareFusion |
| Usage | Intravenous infusion of fluids, medications, and blood products |
| Display | Touchscreen |
| Power Source | AC Power, Internal Battery |
| Connectivity | Ethernet |
| Components | PC Unit, Pump Module, Syringe Module, PCA Module, EtCO2 Module, SpO2 Module |
| Alaris Pump Module Flow Rate Range | 0.1 to 999 mL/hr |
| Alaris Pump Module Occlusion Pressure Settings | Low, Medium, High |
| Alaris PCA Module Drug Library | Configurable |
| Alaris PCA Module PCA Dose Limits | Configurable |
| Alaris EtCO2 Module Technology | Mainstream or Sidestream (depending on sensor) |
| Infusion Modes | Continuous, Intermittent, PCA, TPN |
| Flow Rate Range | 0.1 to 999 mL/hr (Pump Module), 0.1 to 99.9 mL/hr (Syringe Module) |
| Volume to be Infused (VTBI) Range | 0.1 - 9999 ml |
| Accuracy | +/- 5% |
| Alarms | Air-in-line, Occlusion, Low Battery, Infusion complete, etc. |
| Compatibility | Compatible with various IV sets and syringes |